Table A-1. Network Interface Options (2 of 2)
8700-A2-GB25-10
DSL Line Rate
Possible Settings: 144, 272, 400, 528, 784, 1040,1552, 2064
Default Setting: 2064
Determines the fixed line rate of the LTU when AutoRate is disabled, and the maximum
rate to which the unit can be set when AutoRate is enabled.
T
DSL Line Rate is only available when the unit is configured as an LTU.
144 – Available payload rates are 64 and 128 kbps.
272 – Available payload rates are 192 and 256 kbps.
400 – Available payload rates are 320 and 384 kbps.
528 – Available payload rates are 448 and 512 kbps.
784 – Available payload rates are 576, 640, 704, and 768 kbps.
1040 – Available payload rates are 832, 896, 960, and 1024 kbps.
NOTE: DSL Line Rates of 1552 and 2064 kbps are available only on 2 Mbps
termination units.
1552 – Available payload rates are 1088, 1152, 1216, 1280, 1344, 1408, 1472, and
1536 kbps.
2064 – Available payload rates are 1600, 1664, 1728, 1792, 1856, 1920, 1984, and
2048 kbps.
Peer IP Address
Possible Settings: 001.000.000.000 – 223.255.255.255, Clear
Default Setting: 000.000.000.000
Specifies the peer IP address providing the remote management link on the DSL loop.
T
Peer IP Address is only available when the unit is configured as an LTU and the unit
is not running in IP Conservative mode.
001.000.000.000 – 223.255.255.255 – Enter an address for the peer unit. The range for
the first byte is 001 to 223, with the exception of 127. The range for the remaining three
bytes is 000 to 255. The Peer IP address must be in the same subnet as the management
card address.
Clear – Clears the IP address and sets to all zeros.
Circuit Identifier
Possible Settings: ASCII text field , Clear
Default Setting: [blank]
Uniquely identifies the circuit number of the transmission vendor's DSL line for
troubleshooting purposes.
ASCII text field – Enter a maximum of 128 characters. All printable ASCII characters
except the ^ (caret) are allowed.
Clear – Clears the field.