Paradyne Hotwire 8775 User Manual page 84

Tdm sdsl termination units
Table of Contents

Advertisement

A. Configuration Options
Table A-8. SNMP Trap Options (2 of 2)
A-14
General Traps
Possible Settings: Disable, Warm, AuthFail, Both
Default Setting: Both
Determines which SNMP traps are sent to each trap manager.
Disable – No general trap messages are sent.
Warm – Sends trap message for warmStart events.
AuthFail – Sends trap message for authenticationFailure events.
Both – Sends both trap messages.
NOTE: Refer to
SNMP Traps
Enterprise Specific Traps
Possible Settings: Enable, Disable
Default Setting: Disable
Determines if SNMP traps are generated for enterprise-specific events.
Enable – SNMP traps are generated for enterpriseSpecific events.
NOTE: Refer to
Enterprise-Specific Traps
SNMP Traps .
Disable – No enterprise-specific event traps are sent.
Link Traps
Possible Settings: Disable, Up, Down, Both
Default Setting: Both
Determines if SNMP traps are generated for link up and link down for one of the
communication interfaces.
Disable – No linkUp or linkDown SNMP traps are generated.
Up – A linkUp trap is generated when the unit recognizes that one of the communication
interfaces is operational.
Down – A linkDown trap is generated when the unit recognizes a failure in one of the
communication interfaces.
Both – Sends trap messages for detection of both linkUp and linkDown .
NOTE: Refer to
linkUp and linkDown
Traps .
Link Traps Interfaces
Possible Settings: Network, SYNC, All
Default Setting: All
Determines if the SNMP linkUp , SNMP linkDown , and interface-related enterpriseSpecific
traps are generated for the network interface and/or synchronous data (DTE) port.
Network – SNMP trap messages are generated for the network interface.
SYNC – SNMP trap messages are generated for the synchronous data (DTE) ports.
All – SNMP trap messages are generated for the network interface and the synchronous
data (DTE) ports.
February 2001
in Appendix B, Standards Compliance for SNMP Traps .
in Appendix B, Standards Compliance for
in Appendix B, Standards Compliance for SNMP
8700-A2-GB25-10