IBM Token-Ring Network PC Adapter Hardware Maintenance And Service page 89

Hide thumbs Also See for Token-Ring Network PC Adapter:
Table of Contents

Advertisement

PRIMARY ADAPTER NOT PRESENT
Meaning:
Action:
The Advanced Diagnostics cannot locate the
primary adapter in any of the system unit's
I/O ports.
Make sure the adapter is firmly seated in its
slot.
Check the switch settings on the adapter to
make sure that they correspond with the
configuration you have established. See
Chapter 4 for the recommended switch
settings.
Check the switch settings for your system
unit memory.
Run the Advanced Diagnostics program
agaIn.
If the problem continues, run the diagnostics
provided with your IBM Personal
Computer's Guide to Operations to determine
if your computer is operating properly.
PR~MARY
IBM TOKEN-RING NETWORK PC ADAPTER 16600 S
Meaning:
Action:
3-52
No errors were detected while testing the
primary adapter.
None required.