6.8.2
Grade dial-in with
Rugby CLA‑ctive
step-by-step
68
7.
Press the Up/Menu button or Down/Sleep button to edit a selected
character.
Press the Left/Bandwidth button and Right/Volume button to navig-
ate the characters.
8.
Press the Up/Menu button or Down/Sleep button to confirm.
Once grade is entered, the Rugby begins to adjust to grade. Do not
disturb the Rugby during this process.
The values flash while the self-levelling is in process.
Press the Up/Menu button and Down/Sleep button simultaneously to
reset the grade value to zero while in grade entry mode.
Grade Dial-in with Rugby CLA‑ctive
5
4
3
20883_001
1.
Set up the Rugby on a tripod.
2.
Set up the Rugby and the tripod in line with one axis of the job and
align the top of the Rugby in the direction of the axis.
3.
Turn on the Rugby.
4.
Press the OK/Grade button once to start the grade entry mode.
The X-axis grade value will be highlighted.
5.
Press the Down arrow button to select the Y-axis grade value.
6.
Select the grade value.
7.
Press the Up arrow button or Down arrow button to change the
grade value.
Press the OK/Grade button to confirm the selection or wait
10 seconds for auto confirmation.
8.
Once grade is entered, the Rugby begins to adjust to grade. Do not
disturb the Rugby during this process.