Adjusting The Self-Levelling Accuracy - Leica Rugby CLA User Manual

Table of Contents

Advertisement

8.2
Description
Entering calibration
mode step-by-step
Calibrating the X-axis
step-by-step
80
7.
Mark the position of the beam.
8.
Rotate the laser 180° and allow it to self-level.
9.
Mark the opposite side of the second axis.
The Rugby is within its accuracy specification if the four marks are
within ±1.5 mm (±1/16") from the centre.

Adjusting the Self-Levelling Accuracy

In Calibration mode the X-axis calibration screen indicates changes to the
X-axis.
0015891_001
The Y-axis calibration screen indicates changes to the Y-axis.
0015892_001
1.
Enter the calibration menu.
Enter the calibration menu and select XY Calibration. Refer to
4.3.3 Menu Set
2.
Press the OK/Grade button to switch from the X-axis to the Y-axis
screen.
3.
Modify the values as appropriate.
In Calibration mode, the LED does not blink and the laser head con-
tinues to rotate.
When entering Calibration mode, the X-axis calibration screen appears:
2-Calibration.
X
Y
Accuracy Adjustment

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rugby cla-ctiveRugby clh

Table of Contents