Unit select
Temperature
sensitivity
Combo
While a beam is being detected on the main screen,
the digital read out displays the distance the beam
is to the centre point on the Combo. Within the Unit
settings menu, it is possible to select the units of
the distance measurement:
cm
mm
Inches
Feet
Fractional inches
For each change in temperature of ±5 °C (±9 °F) the
Rugby returns to the level position to check if the
change in temperature has led to a change of the
main levelling system. For a more sensitive unit, you
can change the setting to ±2 °C (±4 °F) temperature
change.
Alternatively, you can completely disable this fea-
ture. As a result, changes in temperature are not
monitored for the purposes of the internal levelling
system functionality.
Disabling the feature turns off the con-
trolling mechanism.
This feature also causes non-temperature
related re-levelling for the Rugby CLH.
With the 5 °C/9 °F option, the Rugby CLH
re-levels every 20 minutes. Alternatively,
the 2 °C/4 °F option, causes the
Rugby CLH to re-level every 10 minutes.
When the Temperature sensitivity check
is disabled, a small icon is shown on the
Combo and Rugby.
Available intervals:
Temperature is checked every 5 °C/9 °F
Temperature is checked every 2 °C/4 °F
Off