Calibrating the Y-axis
step-by-step
Exiting calibration
mode
Accuracy Adjustment
1.
Check both sides of the X-axis.
2.
Press the Up/Menu button and Down/Sleep button to modify the
calibration value.
Each step represents approximately 2 arc seconds of
change. Therefore, 5 steps equal approximately 1.5 mm
at 30 m (1/16" at 100').
3.
Press the OK/Grade button to accept the adjusted position and to
switch to the Y-axis calibration screen.
After calibration of the X-axis, the Y-axis calibration screen appears:
1.
Check both sides of the Y-axis.
2.
Press the Up/Menu button and Down/Sleep button to modify the
calibration value.
Each step represents approximately 2 arc seconds of
change. Therefore, 5 steps equal approximately 1.5 mm
at 30 m (1/16" at 100').
3.
Press the OK/Grade button to accept the adjusted position and exit
the calibration screen.
Press the OK/Grade button to accept the adjusted position and exit the calib-
ration screen.