Leica Rugby CLA User Manual page 88

Table of Contents

Advertisement

Alert
88
Symptom
The temperature
check alert screen is
shown.
The "empty battery"
icon flashes.
The beam is not
emitting from all
sides of the laser.
Possible causes and solutions
The Rugby has detected a
change in temperature of 5 °C
and is checking the level posi-
tion.
Wait until procedure
is complete. Refer
to
4.3.2 Menu Set
1-Temperature sensit-
ivity
for changing the
setting between 5 °C,
2 °C or to disable.
This feature also
causes non-temperat-
ure related re-levelling
for the Rugby CLH.
With the 5 °C/9 °F
option, the Rugby CLH
re-levels every 20
minutes. Alternatively,
the 2 °C/4 °F option,
causes the Rugby CLH
to re-level every 10
minutes.
The Rugby has reached a low
battery state and changes the
head speed to 7 rps. If the
Combo detects the Rugby rotat-
ing at 7 rps, it displays a low
battery alert.
Check the battery of
the Rugby.
During this state, the
Smart Target features
are disabled.
Beam masking is activated for
two or more sides of the laser.
To de-activate or change beam
masking, refer to
4.3.2 Menu
Set 1-Beam
masking.
Troubleshooting