Xerox 4215 Reference Manual page 210

Xerox 4215: reference guide
Hide thumbs Also See for 4215:
Table of Contents

Advertisement

COAX COMMUNICATIONS BUFFER
Control Unit Output Area
Address
X'0010'
X'00011
X'0012'
to
X'0013'
X'0014'
to
X'0015'
X'0016'
Continuing next page
D-4
The Control Unit Output Area (CUOA) that occupies locations
X'0010' to X'004F' of the PCIA contains information regarding
orders from the control unit and configuration information. The
CUOA is written by the cluster controller and read by the printer.
Table D-3.
Function
Mode
Bit 0—4
Bit 5
Bit 6—7
Mode
Bit 0—2
Bit 3—4
Bit 5—7
Message
Starting
Address
(MSA)
Message
Length
Order
Code X'01'
Code X'02'
Code X'03'
Code X'05'
Code X'06'
Code X'07'
Control unit output area
Description
Reserved
Enable Set Attribute control code (SCS only)
Ignored
Reserved
00
— Host-directed copy
01
— Host-initiated local copy
10
— Operator-Initiated Local Copy
11
— Reserved
000
— No mode
001
— Data Stream Compatible
mode (DSC) - BSC
101
— Data Stream Emulation
mode (DSE) - SNA
110
— LU-1 mode
111
— Reserved
These two bytes define the point in the message
area where the current message begins.
These bytes define the length of the current message.
If the length is zero, nothing is printed.
In SCS mode, data wraps from the end of the
character buffer to address X'0050.'
In non-SCS mode, data is loaded to the end of the
character buffer only.
Abort
System status available
Print processing
Load translate tables (ignored)
DSC (ignored)
DSC load structured field (ignored)