The Setup menu

Accessing the
1
Setup menu
2
Changing weld-
1
ing parameters
2
3
4
Exiting the
1
Setup menu
Parameters for
MMA welding
50
Use the welding process button to select the process for which the Setup
parameters are to be changed:
MMA welding
MMA welding with Cel electrode
TIG welding
-
MMA welding
-
MMA welding with Cel electrode
-
TIG welding
+
Press the setting value and welding process buttons together
-
After releasing the buttons, the code for the first parameter in the Setup
menu is displayed
Turn the adjusting dial to select the required parameter
Press the adjusting dial to display the preset value of the parameter
Turn the adjusting dial to change the value
-
the new value becomes effective immediately
-
exception: when restoring the factory settings, press the adjust-
ing dial after changing the value to activate the new value.
Press the adjusting dial to return to the list of parameters
Press the setting value or
welding process button to exit the Setup menu