Vertiv NetSure 731 C62 Series User Manual page 54

Table of Contents

Advertisement

Vertiv™ NetSure™ 731 C62 Series Power System User Manual
Figure 4.38 Settings screen upon user level
Lang:
English
Tzone: GMT+08: 00
Date:
2016-07-04
Time:
15:23:22
If the 'Reset Para' is set to 'Y', press the ENT key will pop up the screen shown in Figure 4.39.
Figure 4.39 Prompt screen for resetting system
Press the ESC key to cancel the resetting. Press the ENT key to execute the resetting. At this time, all the parameters
will return to the default value. It is recommended to execute system resetting when the controller cannot work
normally through the method of powering off or restoration.
If the 'Reset PWD' is set to 'Y', the password of the controller will be reset to the factory default password after
pressing the ENT key.
Press ▲ or ▼ to select the parameter you need and press ◄ or ► to select the parameter value. Then press ENT to
confirm.
The value description of the system parameters is listed in Table 4.17.
Table 4.17 Description of the system parameter setting
Parameter
Range
Lang
Chinese, English
Tzone
/
Date
2000 ~ 2099
Time
00:00 ~ 23:59
System Type
48V/100
48V/300
48V/500
System Type
48V/1000
48V/SET
AC + Rect,
Swtich.S.C,
Sys Work Mode
AC + S + W,
S + W
Stable
CtrlMode
Save
ComDownLoad
Y, N
Reset PWD
Y, N
24
System Type:
48V/SET
48V/300
Sys Work Mode:
AC + Rect
Confirm:
ENT Continue
ESC Quit
Factory setting
English
/
/
/
48V/300
48V/300
AC + Rect
Save
N
N
Ctrlmode:
ComDownLoad: N
Save
Reset PWD:
ComDownload: N
N
Reset Para:
Reset PWD:
N
N
Op1 PWD:
******
Reset Para:
N
Value description
Set it according to your requirement
Set it according to the actual instance
Set the time according to the current actual time, regardless of whether it
is a leap year or not
Set the time according to the current actual time
The system type of the controller has been set according to the actual
instance before the controller is delivered with power supply system. You
do not need to change the value except that the controller needs to be
replaced with a new one.
After changing the type, the controller will restart and other parameters
will resume the default. You need to reset and change some parameters
according to the battery and other equipment configured with the system
Set it according to the system configuration
In the optoelectronic hybrid mode, the system will make more use of solar
energy when choosing whether to focus on stability or saving
First set the value to 'Y', when you wish to use Bootload for program
upgrade
Whether resetting the password to the default
Op1 PWD: ******
Op2 PWD: ******
Adm PWD: ******
Op2 PWD: ******
SMDCU Batt:
N
Adm PWD: ******
ClearDCUBatt: N