Using a #2 Phillips screwdriver, remove the top screw (C1) to free
6.
the Lift Motor ground wire (E). Hand tighten the top screw to hold the MCB
assembly (C) in position on the Frame until reassembly.
7.
after noting the connector locations.
Note: Be sure to note where all cables attach for re-assembly.
D - Power inlet
(line)
The MCB shown is on an E626 machine.
C1
C
The MCB shown is on a Schwinn
D - Power inlet (neutral)
E - Lift motor common
(neutral)
E - Lift motor CW
(line)
E - Lift motor CCW
(line)
E - Lift motor position
potentiometer
G - Servo control
F - Lift motor wire
(to Console)
78
E - Lift
motor
ground
E
™
470 machine.