NOTICE: It is necessary to remove the Shrouds for this procedure. Refer to the "Replace the Shrouds" procedure.
To reduce the risk of electrical shock or unsupervised usage of the equipment, always unplug the power cord from
!
the wall outlet and the machine and wait 5 minutes before cleaning, maintaining or repairing the machine. Place the
power cord in a secure location.
Note: Your machine may not match the image. For reference only.
1.
Carefully remove the Shrouds. Refer to the "Replace the Shrouds"
2.
procedure in this manual.
Locate the Lift Motor Cable (E) that goes from the Lift Motor (A) to
3.
the Motor Control Board (MCB) assembly (C) on your machine.
E—Lift Motor Cable, Lower (Lift Motor to MCB)
F—Lift Motor Wire, Upper (MCB to Console)
G—Servo Control Wire (MCB to Servo Motor)
H—Speed Sensor Cable (Speed Sensor to Servo
Motor)
Note: Be sure to note where all cables are routed
for re-assembly.
Remove the zipties (Z1, Z2) that hold the cables.
4.
Loosen and remove the screws (B) that attach the
5.
MCB cover to the MCB assembly (C). Carefully remove
the MCB cover.