Multivalue signature
26
RC8BX402
2. Just like adding a parameter, you have the ability to select existing assets and points which act as a
reference to the name once a mimic is created from the template. Select the asset and the parameter
from the drop down menus - notice that the tooltip will change to the point name reference, and
then press 'OK' button.
3. The multivalue signature can be placed where necessary.
4. To edit the parameter, add states and images, right click on the signature and select 'Configure' .
5. Select a default image if required
6. Enter a value for indicate the first state. For example, a freezer's defrost cycle could be illustrated by
indicating a normal state and a defrost state, so it would be '0' or '1' (or the correct enumeration) for
'Normal' or 'Defrost' respectively. Note that it is also possible to enter ranges of values, such as 1,3,15,
as well as 1,3,15-18, which will then share the same image. Then select an image for that state from
the list.
7. Press the 'Add' button to add another state and enter as many states as possible. When finished, it
should look something like the example below.
When 'OK' is pressed, the dialogue box will change (and allow you to show the graphical image for each
state by pressing the 'Show' button. When 'OK' is pressed again, the multivalue signature will change to
the default image.