8. Commissioning Quick Task List
AK-EM 100 Installation Guide
The Commissioning Overview list is to provide a quick reference guide for the Commissioner
and contains a list of tasks they would typically perform when installing the AK-EM 100 system
after the physical connections are completed. The section following this task list provides a more
detailed look at the procedures for each task.
In sequential order - they would typically perform the following 4 steps:
Establish network communication
This features the Commissioning Toolbox, where details of the site would be entered such as the
network connections to be configured and established for the controllers to be able to connect to the
Gateway, perform the runs to upload the uploaded, and view the details of the data runs.
Establish communication with Gateways and Controllers.
Tasks include:
1.
Upload the controller information so that we can verify that:
a.
Correct number of controllers is visible on the uploaded list
b.
Correct type of controllers is visible on the uploaded list
All the DES files should be available.
Initial configuration of refrigeration system
Get the refrigeration system up and running.
Tasks include:
2.
Once the controller information is uploaded, the individual set point values for the parameters
can be configured. In this initial configuration stage it is not necessary for the Commissioning
Engineer to adjust the set point values with great accuracy, but just enough to have the system
up and running.
Fine tuning of refrigeration system
Ensure system is fully running with accuracy and can output the correct information for all reports.
Tasks include:
3.
Continue with adjustment of Set Point Values with greater accuracy and for all the parameters.
4.
Define enumeration points, include or exclude them in trending.
5.
Select which page (basic or advanced) the parameter details link to.
6.
The option of importing and exporting saved configuration settings for multiple assets which
share the same settings.
7.
Once the main configuration has been completed, then certain functions can be redefined from
the Administration section. This would include adding more enumeration displays, setting up the
users and groups tables, loading the DES file which contains the controller settings, and saving
the configuration setting.
Configuration of UI
Set up the Graphical User Interface on the store layout so that there is a Visual Representation of a two
tier site structure showing top level site floor layout with cabinets, and then 2nd level: the individual
cabinet detail.
Tasks include:
8.
Uploading the images for the store.
9.
Creating templates and/or mimic, creating the top level mimic.
10. Assigning parameters to the mimics based on a template.
© Danfoss 05-2011
RC8BX402