• The use of a atomiser set other than that
specified or provided by the manufacturer
of this device can lead to an increase in
electromagnetic emissions or a decrease in
the device's electromagnetic immunity; this
can result in faulty operation.
• Keep portable RF communication devices
(including peripheral equipment, such as
antenna cables or external antennas) at least
30 cm away from all device parts, including all
cables included in delivery.
• Failure to comply with the above can impair
the performance of the device.
11. WHAT IF THERE ARE
PROBLEMS?
Problem/
Possible cause/remedy
question
The atomiser
1. Too much or too little
produces no
medication in the atomiser.
or too little
Minimum: 2 ml,
aerosol.
Maximum: 8 ml.
2. Check nozzle for blockages.
Clean nozzle if necessary (e.g.
by rinsing out). Then start
using the atomiser again.
IMPORTANT: carefully pierce
the fine holes only from the
underside of the nozzle.
3. Atomiser not held vertically.
The atomiser
4. Unsuitable medication fluid
produces no
added for nebulisation (e.g.
or too little
too viscous).
aerosol.
The medication fluid should be
prescribed by a doctor.
The output is
Kinked hose, clogged filter, too
too low.
much inhalation solution.
What
Please consult your doctor in
medications
relation to this matter.
are suitable
As a rule, all medication that is
for inhaling?
suitable and approved for device
inhalation can be inhaled.
There is
This is normal and is due
inhalation
to technical reasons. Stop
solution
inhalation once the atomiser
residue in the
starts to make a notably different
atomiser.
sound.
Problem/
Possible cause/remedy
question
What should
1. On babies, the mask should
be taken
cover the mouth and nose to
into account
ensure effective inhalation.
when
2. On children, the mask should
using the
also cover both the nose and
device with
mouth. It is not very useful to
babies and
carry out nebulisation next
children?
to someone who is sleeping,
as in this case not enough of
the medication will reach the
lungs.
Note: inhalation should only be
carried out under the supervision
of an adult and with their
assistance, and the child should
not be left alone.
Why should
There are two reasons for this:
the atomiser
1. To ensure a therapeutically
be replaced
effective particle spectrum, the
regularly?
nozzle hole must not exceed
a specific diameter. Due
to mechanical and thermal
stresses, the plastic is subject
to a certain degree of wear.
The atomiser insert
particularly delicate. This can
also alter the composition
of the aerosol droplets,
which directly affects the
effectiveness of the treatment.
2. Regularly changing the
atomiser is also recommended
for hygiene reasons.
Should each
Yes, this is absolutely essential
person have
for hygiene reasons.
their own
atomiser?

12. DISPOSAL

For environmental reasons, do not dispose of the
device in the household waste.