IH 21
EN Nebuliser
Instructions for use

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IH 21 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Beurer IH 21

  • Page 1 IH 21 EN Nebuliser Instructions for use...
  • Page 2: Table Of Contents

    Serial number they contain. 30 minute operation, followed by a With kind regards 30 Min. ON / 30 minute break before operation Your Beurer team 30 Min. OFF continues. Area of application Protected against foreign objects equal to IP 21 This nebuliser is a device used for the nebulisation or greater than 12.5 mm in diameter and...
  • Page 3: Safety Information And Warnings

    Please note: • The IH 21 nebuliser must only be used with suitable For treatment, only use parts indicated by your doc- atomisers and with the appropriate accessories. The tor according to the particular diagnosis.
  • Page 4: Description Of Device And Accessories

    4. Description of device and General notes accessories Important Overview of the nebuliser • Use the unit only: – On humans, – for its intended purpose (aerosol inhalation) and in the manner described in these instructions for use. • Any improper use can be dangerous! •...
  • Page 5: Initial Use

    5. Initial use • Lay the mains cable in such a way that no one can trip over it. Setup • To disconnect the nebuliser from the mains after use, Remove the unit from the packaging. Place it on a flat first switch off the device and then remove the plug surface.
  • Page 6 The baby mask is not inclu- • Switch off the nebuliser after treatment using the on/ ded in delivery with the IH 21. You can find an overview off switch [3] and disconnect it from the mains.
  • Page 7: Changing The Filter

    8. Press the On/Off switch [2] on the Warning back of the nebuliser. To start the • Do not use the nasal douche in combination with application, place one finger over other medication or essential oils. the cover hole [22] on the container. Important Note •...
  • Page 8: Cleaning And Disinfection

    2. Replace the filter cap [5] containing the new filter. etc. must be cleaned with hot but not boiling water 3. Check that the filter cap is firmly in place. after each use. Carefully dry all components using a soft cloth. Once 8.
  • Page 9: Disposal

    10. Troubleshooting sure that the volume is sufficient to fully submerge the parts in the solution. Problem/ Possible Cause/Remedy • Leave the components in the vinegar solution for 30 Question minutes. The atomiser 1. Too much or too little medicine •...
  • Page 10: Technical Specifications

    More information can be own atomiser? obtained from the relevant medicine manufacturer. 11. Technical specifications 12. Replacement parts and wearing parts Model IH 21 Type IH 21/1 Designation Material Dimensions Yearpack (contains Mouth- PP/ PVC 601.22...
  • Page 11: Warranty / Service

    • The use of the device may be limited in the presence A warranty claim shall only be considered if the buyer of electromagnetic disturbances. This could result in can provide Beurer, or an authorised Beurer partner, issues such as error messages or the failure of the with display/device.