Extron electronics PlenumVault Installation Manual

Extron electronics PlenumVault Installation Manual

Direct view systems featuring the pvca 452 controller amplifier
Table of Contents

Advertisement

Quick Links

PlenumVault Direct View
Systems
featuring the PVCA 452 Controller Amplifier
Installation Guide
PlenumVault
68-3647-01, Rev. A
11 23

Advertisement

Table of Contents
loading

Summary of Contents for Extron electronics PlenumVault

  • Page 1 PlenumVault Direct View Systems featuring the PVCA 452 Controller Amplifier Installation Guide PlenumVault 68-3647-01, Rev. A 11 23...
  • Page 2 Safety Instructions Safety Instructions • English Instructions de sécurité • Français AVERTISSEMENT : Ce pictogramme, , lorsqu’il est utilisé sur le WARNING: This symbol, , when used on the product, is intended to produit, signale à l’utilisateur la présence à l’intérieur du boîtier du produit alert the user of the presence of uninsulated dangerous voltage within the d’une tension électrique dangereuse susceptible de provoquer un choc product’s enclosure that may present a risk of electric shock.
  • Page 3 Extron, Cable Cubby, ControlScript, CrossPoint, DTP, eBUS, EDID Manager, EDID Minder, eLink, Flat Field, FlexOS, Glitch Free, Global Configurator, Global Scripter, GlobalViewer, Hideaway, HyperLane, IP Intercom, IP Link, Key Minder, LinkLicense, LockIt, MediaLink, MediaPort, NAV, NetPA, PlenumVault, PoleVault, PowerCage, PURE3, Quantum, ShareLink, Show Me, SoundField, SpeedMount, SpeedSwitch, StudioStation, System I , TeamWork, TouchLink, V-Lock, VideoLounge, VN-Matrix, VoiceLift, WallVault, WindoWall, XPA, XTP, XTP Systems, and ZipClip...
  • Page 4 FCC Class A Notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. The Class A limits provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 5 Conventions Used in this Guide Notifications The following notifications are used in this guide: WARNING: Potential risk of severe injury or death. AVERTISSEMENT : Risque potentiel de blessure grave ou de mort. CAUTION: Risk of minor personal injury. ATTENTION : Risque de blessure mineure. ATTENTION: •...
  • Page 7: Table Of Contents

    Compliance ........... 3 Room Considerations ........3 Stage 3: Installing the FF 120 Ceiling Speakers Inventory — PlenumVault Direct View System ..6 ..30 Items Not Included ..........7 1. Cut Ceiling Tile for the Speakers ....31 Installation Tools ..........7 2.
  • Page 9: Introduction

    These systems include network connectivity for web-based asset management, monitoring, and control. The PlenumVault Direct View System is used in a suspended ceiling room with a wood or concrete structural ceiling foundation. It uses the PVM 220 PlenumVault Mounting Kit to securely mount and conceal system components in the plenum space above the suspended ceiling.
  • Page 10: Application Diagram

    FF 120 Flat Field Speakers Flat Panel Display eBUS HDMI Extron D IS WPD 110 A Pass-Through Wallplate tr o Extron Laptop EBP 100 eBUS Button Panel Figure 8. PVDV 101 PlenumVault Direct View System PlenumVault Direct View Systems • Introduction...
  • Page 11: Before You Begin - Planning The Installation

    Americans with Disabilities Act (ADA) Compliance When planning where to install the PlenumVault Direct View System, consider factors affecting accessibility of the system such as the height of devices from the floor (for example the EBP button panels), distance from obstructions, and how far a user must reach to press any device buttons.
  • Page 12 (wall, podium, or furniture) • Cabling obstacles: studs, utility pipes, power supply location (consider if raceway installation is needed) • Network drop for PVCA 452: ceiling cabled to PlenumVault PVM 220 location PlenumVault Direct View Systems • Introduction...
  • Page 13 Each speaker covers Student Desks one-fourth of Windows listening area. Speaker Location eBUS Button Panel Location Teacher’s Teacher’s Laptop/PC Desk Desk Wallplate Location Display Location Figure 10. Example Classroom with Four Speaker Installation PlenumVault Direct View Systems • Introduction...
  • Page 14: Inventory - Plenumvault Direct View System

    Inventory — PlenumVault Direct View System The standard PVDV 101 PlenumVault Direct View System (part number 42-300-01) contains the following items and their corresponding hardware. Check to ensure that all items have been received. Actual products included in each kit may vary as system kits are customizable.
  • Page 15: Items Not Included

    Fish tape, pull string, and electrical tape (for taping fish tape to pull string) • Standard screwdriver set and • Extron tweeker Zip ties • Cable cutters (to cut safety wire) • Vacuum cleaner PlenumVault Direct View Systems • Introduction...
  • Page 16: Optional Items

    Optional Items The optional Extron products suggested below can be added to or substituted for items in the standard PlenumVault Direct View System. Some of these items may also be suitable for the Digital WallVault or PlenumVault Systems. • Accessories NBP Network Button Panel •...
  • Page 17: Installation Overview

    Installation Overview Before Getting Started Carefully check inventory of PlenumVault Direct View System packages, input and output devices, any optional accessories, and installation hardware before starting. NOTES: • Additional installation hardware is needed for this installation, and should be Items Not Included supplied by the installer.
  • Page 18 Use the Software to Configure and Control the PVCA 452 (page 47) Download the Latest PVCA 452 Firmware (page 48) NOTE: This list is also provided on the rear cover of this guide. PlenumVault Direct View Systems • Installation Overview...
  • Page 19 +V +S -S G CLASS 2 WIRING Audio HDMI Audio OUTPUT RELAY RS 232 (Display Control) Extron VLR 302 HDMI A B C HDMI Extron WPD 110 A HDMI Pass-Thru Display GlobalViewer Campus Communication Suite PlenumVault Direct View Systems • Installation Overview...
  • Page 20: Stage 1: Installing The Pvm 220

    Follow the installation instructions provided by the display and display mount manufacturer. the marked location. PlenumVault Direct View System (PVM 220 PlenumVault Mount Kit) Device Mounting Plate PVCA 452 Power Supply...
  • Page 21 Building installation wiring is to be protected by a UL Listed circuit breaker rated 20 A. • Observe all local and national building and safety codes, UL requirements, and ADA Accessibility Guidelines. • “Only for use with Extron’s UL Listed ITE or Audio/Video equipment.” or equivalent. PlenumVault Direct View Systems • Installing the PVM 220...
  • Page 22: Remove The Device Mounting Plate From The Access Door

    Thread the looped end of the suspension cable though the bolt eyehole, pass the rest of the cable through the loop and tighten. Allow each cable to hang down. PlenumVault Direct View Systems • Installing the PVM 220...
  • Page 23: Suspend The Main Pvm 220 Enclosure From The Ceiling

    Repeat steps a through c for each corner. e. Adjust the cable tension through all locks, making each cable taut without lifting the PVM 220 off the T-grid. Pass cable through the cable locks. PlenumVault Direct View Systems • Installing the PVM 220...
  • Page 24: Run Ac Power Wiring To The Ac Module In The Pvm 220

    Use 12 AWG gauge solid copper wire only, as required by the installed power receptacles. Run the power cable through metal conduit and wire it into the PVM 220 power module. To do this, follow the instructions on the next page. PlenumVault Direct View Systems • Installing the PVM 220...
  • Page 25: Run Signal, Wpd And Control Cables To The Pvm 220

    WPD 110 A to the display. Speaker cables • SPK 18 cables connect FF 120 ceiling speakers to SPK 18, 35 ft (Qty. 2) the PVCA 452 amplifier. 26-627-35 PlenumVault Direct View Systems • Installing the PVM 220...
  • Page 26 Tighten down the cable grip until the cables Run the signal and control cables into the are held firmly. PVM 220 through the knockouts. Avoid damaging or bending cables at too sharp an angle. PlenumVault Direct View Systems • Installing the PVM 220...
  • Page 27: Install Devices Onto The Device Mounting Plate

    Example: 24 x 24 inch Ceiling Tile b. With the access door open, insert the cut ceiling tile into the door frame (see image on the next Cut the ceiling tile. page). PlenumVault Direct View Systems • Installing the PVM 220...
  • Page 28: Install The Device Mounting Plate Onto The Access Door

    Ceiling Tile Device Mounting Door Frame Insert (see Rear Panel Features and Cabling on page Plate Screws 34). For installation and setup of optional NOTE: devices, see the corresponding guide or manual PlenumVault Direct View Systems • Installing the PVM 220...
  • Page 29: 10. Attach The Door Tether To The Door

    (see image at right). For full safety, secure both latches. To secure the latch from opening tighten the set screw onto the latch. Secure the door latch. PlenumVault Direct View Systems • Installing the PVM 220...
  • Page 30: Stage 2

    Do not bend the cables at 90 degrees. • Secure cables with cable clamps to provide suitable stain relief and maintaining the cable bend. PlenumVault Direct View Systems • Installing the WPD Wallplate and EBP 100...
  • Page 31: Step 2 - Install The Wpd 110 A Wallplate

    WPD 110 A ring or wall box. Insert the appropriate connectors NOTE: See the next page for audio connector wiring. into the WPD 110 A ports. PlenumVault Direct View Systems • Installing the WPD Wallplate and EBP 100...
  • Page 32 WPD wallplate. • Use the included hole plug to conceal the audio connector opening. • Use the included overlay to conceal the openings in the wallplate. Overlay label PlenumVault Direct View Systems • Installing the WPD Wallplate and EBP 100...
  • Page 33: Step 3 - Install The Ebp 100 Ebus Button Panel

    Attach the faceplate to the EBP by aligning the openings of the faceplate with the buttons and knob and with the LEDs and place the faceplate against the unit. The magnetic catches fasten the faceplate onto the unit. PlenumVault Direct View Systems • Installing the WPD Wallplate and EBP 100...
  • Page 34 Up = on = 1, Down = off = 0 For the EBP 100, the factory default BUS ID is 000011, and the corresponding address is 3. The BUS ID can be changed to any valid value. PlenumVault Direct View Systems • Installing the WPD Wallplate and EBP 100...
  • Page 35 +V pin appropriately (see figure 11 on the following page). PlenumVault Direct View Systems • Installing the WPD Wallplate and EBP 100...
  • Page 36 Turn the screws on the front of the mounting bracket clockwise so that the locking arms rotate and secure the bracket against the wall. Do not overtighten the locking arms. PlenumVault Direct View Systems • Installing the WPD Wallplate and EBP 100...
  • Page 37 Attach the faceplate to the EBP: align the faceplate openings with the buttons, knob (if applicable), and LEDs (if applicable) and place the faceplate against the unit ( ). Magnetic catches hold the faceplate securely to the front of the unit. PlenumVault Direct View Systems • Installing the WPD Wallplate and EBP 100...
  • Page 38: Stage 3

    What it does: Receives and outputs audio signal from the PVCA 452 amplifier. • Cabling for the Speakers Speaker Installation: SPK 18, 35 ft Speaker cable (connects ceiling speakers to the • PVCA 452 amplifier) PlenumVault Direct View Systems • Installing the FF 120 Ceiling Speakers...
  • Page 39: Cut Ceiling Tile For The Speakers

    • Ne créez pas de court-circuit entre les câbles des enceintes au risque d’endommager les enceintes. Remove terminal cover and attach clamp. PlenumVault Direct View Systems • Installing the FF 120 Ceiling Speakers...
  • Page 40 • Le fait de plier l’attache de façon répétitive peut la casser. Attach safety cable. To wire the speaker, see the next page. PlenumVault Direct View Systems • Installing the FF 120 Ceiling Speakers...
  • Page 41: Terminate The Speaker Cables From The Pvca 452 Amplifier

    NOTE: By default, the amplifier is set for dual mono output. Use the Product Configuration Software change the setting to stereo if desired. For full details, see the PVCA 452 User Guide, available online at www.extron.com. PlenumVault Direct View Systems • Installing the FF 120 Ceiling Speakers...
  • Page 42: Stage 4

    Connector (for example, a PVCA 452, 2 or 4 speakers, an EBP 100, and a VoiceLift Microphone system). Tie Wrap 3" 16 (5 mm) Max. SECTION A–A Power Supply Output Cord PlenumVault Direct View Systems • Installing the PVCA 452...
  • Page 43 Audio Input AUDIO Ring Ring Sleeve Sleeves Ring Balanced Audio Input Balanced Mono Input (high impedance) Do not tin the wires! Sleeves Sleeves Sleeves Unbalanced Stereo Input Unbalanced Mono Input Audio Input PlenumVault Direct View Systems • Installing the PVCA 452...
  • Page 44 To verify the polarity before connection, plug in the power supply with no load and check the output with a voltmeter. • Pour vérifier la polarité avant la connexion, brancher l’alimentation hors charge et mesurer sa sortie avec un voltmètre. PlenumVault Direct View Systems • Installing the PVCA 452...
  • Page 45: Outputs

    — For applications using HDMI ARC (Audio Return Channel), connect an HDMI cable between this port and the HDMI ARC supported input on the TV. CEC control signals are also available on this port. PlenumVault Direct View Systems • Installing the PVCA 452...
  • Page 46: Control Ports

    Projector, IR Output Display, or Unidirectional IR Source Device To Projector, Panel Display, or the Wired Ground IR Remote of a Source Device IR or RS-232 Output 3/16" (5 mm) max. PlenumVault Direct View Systems • Installing the PVCA 452...
  • Page 47 Extron IPA T RLY4 or similar device, you can use this port as a digital output. When a port is configured for digital output, it offers two output states: on and off. PlenumVault Direct View Systems • Installing the PVCA 452...
  • Page 48 Insert Twisted Pair Wires been set to the device serial number. Passwords are case sensitive. Performing a Reset to Factory Defaults sets the password to extron. RJ-45 Connector Pins: Activity Link PlenumVault Direct View Systems • Installing the PVCA 452...
  • Page 49: Front Panel Features

    — Lights green when CEC control signal is transmitting. LAN LEDs — 1000 LED — Indicates Single 1000Base-T network connection • LINK LED — Indicates link status • ACT LED — Indicates network activity • PlenumVault Direct View Systems • Installing the PVCA 452...
  • Page 50: Optional Accessory Installation - Priority Page Sensor (Pps 35)

    Using the hook-and-loop fastener, attach the PPS 35 to the front grille of a paging system speaker that is located within fifty feet of the PVCA 452 (see image at right). Run the attached cable to the PVCA 452 location. PlenumVault Direct View Systems • Installing the PVCA 452...
  • Page 51: Optional Accessory Installation - Priority Page Sensor Kit (Pps 25)

    Priority Page Sensor Kit Included Parts: • Priority Page Sensor (part number 70-619-01) • UL Listed junction box with a cable clamp and a lid • 35 feet (10.7 m) of sensor cable PlenumVault Direct View Systems • Installing the PVCA 452...
  • Page 52: Installation Procedure (Pps 25)

    For a 4/8 ohm system, wrap 2 to 4 loops. Open the sensor and loop a wire around the Close and latch the top of the Priority Page sensor. Sensor. Reconnect the speaker cable to the speaker. PlenumVault Direct View Systems • Installing the PVCA 452...
  • Page 53: Testing And Adjustment Procedure

    If the program fails to mute the classroom audio during a page, increase the audio sensitivity. • If the classroom audio is muted without a page occurring, press decrease the audio sensitivity. PlenumVault Direct View Systems • Installing the PVCA 452...
  • Page 54: Stage 5: Configuring The Pvdv 101 System

    Figure 16. PCS on the Extron Website Submit any required information to start the download. Follow the on-screen instructions to download and install the program on your PC. PlenumVault Direct View Systems • Stage 5: Configuring the PVDV 101 System...
  • Page 55: Using The Software

    Passwords are case sensitive. Performing a Reset to Factory Defaults (see the PVCA 452 User Guide for instructions) sets the password to extron. Refer to the PVCA 452 Help File in PCS for configuration options. PlenumVault Direct View Systems • Stage 5: Configuring the PVDV 101 System...
  • Page 56: Downloading The Latest Pvca 452 Firmware

    Click Download ( Follow the on-screen instructions to download the firmware to your PC. Once firmware is downloaded, use Toolbelt or PCS to update the firmware on the device. PlenumVault Direct View Systems • Stage 5: Configuring the PVDV 101 System...
  • Page 57: Outline Of Installation Steps For Plenumvault Digital Systems

    Stage 5 — Configuring the PVDV 101 System Download and Install Software (page 46) Use the Software to Configure and Control the PVCA 452 (page 47) Download the Latest PVCA 452 Firmware (page 48) PlenumVault Direct View Systems • Stage 5: Configuring the PVDV 101 System...
  • Page 58 Extron Warranty Extron warrants this product against defects in materials and workmanship for a period of three years from the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty workmanship and/ or materials, Extron will, at its option, repair or replace said products or components, to whatever extent it shall deem necessary to restore said product to proper operating condition, provided that it is returned within the warranty period, with proof of purchase and description of malfunction to: USA, Canada, South America,...

Table of Contents