11.3. Extended Status Registers

Modbus
CAN
RTU
Open
Register
Index
2001
-
2002
-
2003
-
2004
-
2005
-
2006
-
2007
-
2008
-
2009
2009
2009
2009
2009
2009
2009
-
-
-
-
-
-
-
2010
2010
-
-
-
-
-
-
201 1
201 1
-
-
-
-
-
-
2012
2012
-
-
-
-
-
-
2013
2013
-
-
-
-
-
-
2014
2014
-
-
-
-
-
-
2015
2015
-
-
-
-
-
-
2016
2016
-
-
-
-
-
-
11.3.1. Status Word 2 - Register 2001
11.3.1. Status Word 2 - Register 2001
Status Word 2 provides an optional additional status word which may be used in additional or as an alternative to the status word
Status Word 2 provides an optional additional status word which may be used in additional or as an alternative to the status word
in register 6. This status word is the first word in a block of 16 registers which may be read using a single "Read Multiple Registers"
in register 6. This status word is the first word in a block of 16 registers which may be read using a single "Read Multiple Registers"
command enabling an efficient method to transfer important status information.
command enabling an efficient method to transfer important status information.
Bit
Bit
0
1
2
3
4
5
6
6
6
Speed Set-point Reached (At Speed)
Speed Set-point Reached (At Speed)
Speed Set-point Reached (At Speed)
7
8
9
10
1 1
12
Switching Frequency Reduction
13
14
15
11
56 | Fieldbus Guide | Version 1.02
Sub
PDO
Parameter
Index
Map
Number
-
-
-
-
-
-
-
-
-
-
-
-
-
-
P0-08
-
-
P0-09
-
-
-
-
-
-
-
-
-
-
-
-
-
-
P0-01
P0-01
P0-01
P0-01
P0-01
P0-01
P0-01
-
-
-
-
-
-
-
-
-
-
-
-
P0-02
P0-02
P0-02
P0-02
P0-02
P0-02
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
P0-05
P0-05
P0-05
P0-05
P0-05
P0-05
-
-
-
-
-
-
-
-
-
-
-
-
P0-20
P0-20
P0-20
P0-20
P0-20
P0-20
-
-
-
-
-
-
-
-
-
-
-
-
P0-07
P0-07
P0-07
P0-07
P0-07
P0-07
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Definition
Definition
Ready
Ready
Running
Running
Tripped
Tripped
Standby
Standby
Fire Mode
Fire Mode
Reserved
Reserved
Below Minimum Speed
Below Minimum Speed
Overload
Mains Loss
Heatsink > 85°C
Control Board > 80°C
Reverse Rotation
Reserved
Live Toggle Bit
Upper
Lower
byte
Byte
-
Status Word 2
-
Motor Output Speed
-
Motor Output Current
-
Motor Output Power
-
IO Status Word
-
Motor Output Torque
DC Bus Voltage
Heatsink Temperature
Analog Input 1
Analog Input 1
Analog Input 1
Analog Input 1
Analog Input 1
Analog Input 1
Analog Input 1
Analog Input 2
Analog Input 2
Analog Input 2
Analog Input 2
Analog Input 2
Analog Input 2
-
-
-
-
-
-
Analog Output
Analog Output
Analog Output
Analog Output
Analog Output
Analog Output
PI Output
PI Output
PI Output
PI Output
PI Output
PI Output
Internal Temperature
Internal Temperature
Internal Temperature
Internal Temperature
Internal Temperature
Internal Temperature
Motor Output Voltage
Motor Output Voltage
Motor Output Voltage
Motor Output Voltage
Motor Output Voltage
Motor Output Voltage
-
-
-
-
-
-
IP66 Pot Input value
IP66 Pot Input value
IP66 Pot Input value
IP66 Pot Input value
IP66 Pot Input value
IP66 Pot Input value
-
-
-
-
-
-
Trip Code
Trip Code
Trip Code
Trip Code
Trip Code
Trip Code
Bit is HIGH under the following conditions:
Bit is HIGH under the following conditions:
No trip / fault
No trip / fault
No mains loss
No mains loss
Hardware enable input is present
Hardware enable input is present
Drive running
Drive running
Drive tripped
Drive tripped
In Standby Mode
In Standby Mode
Fire mode is active
Fire mode is active
N/A
N/A
Drive is enabled
Drive is enabled
Output Frequency = Set point
Output Frequency = Set point
Drive is enabled
Drive is enabled
Output Frequency / Speed < P-02
Output current > P-08
Mains power not detected
Heatsink temperature > 85°C
Control PCB temperature > 80°C
PWM switching frequency is reduced from set value
Motor rotates is in reverse direction
N/A
This bit will toggle each time this register is read
Format
Type
Scaling
WORD
R
See Below
S16
R
1dp, e.g. 100 = 10.0Hz
U16
R
1dp, e.g. 100 = 10.0A
U16
R
2dp, e.g. 100 = 1.00kW
WORD
R
See Below
U16
R
4096 = 100%
U16
R
600 = 600 Volts
S16
R
50 = 50°C
S16
S16
R
R
R
1dp, e.g. 500 = 50.0%
1dp, e.g. 500 = 50.0%
1dp, e.g. 500 = 50.0%
U16
U16
R
R
R
R
1dp, e.g. 500 = 50.0%
1dp, e.g. 500 = 50.0%
1dp, e.g. 500 = 50.0%
1dp, e.g. 500 = 50.0%
U16
U16
R
R
R
1dp, e.g. 500 = 50.0%
1dp, e.g. 500 = 50.0%
1dp, e.g. 500 = 50.0%
U16
U16
R
R
R
R
1dp, e.g. 500 = 50.0%
1dp, e.g. 500 = 50.0%
1dp, e.g. 500 = 50.0%
1dp, e.g. 500 = 50.0%
S16
S16
R
R
R
50 = 50°C
50 = 50°C
50 = 50°C
U16
U16
R
R
R
R
200 = 200 Volts RMS
200 = 200 Volts RMS
200 = 200 Volts RMS
200 = 200 Volts RMS
U16
U16
R
R
R
1dp, e.g. 500 = 50.0%
1dp, e.g. 500 = 50.0%
1dp, e.g. 500 = 50.0%
U16
U16
R
R
R
R
See Below
See Below
See Below
See Below
www.invertekdrives.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Optidrive E3 ODE-3 Series and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Optidrive compact 2-basic opc-2-e series

Table of Contents