10.7. Profibus DP Gateway Features – OD-PROFB-IN
Complete PROFIBUS-DP slave functionality according to IEC 61 158.
Supports all common baud rates up to 12 Mbit (detected automatically).
Up to 64 bytes of I/O data in each direction, allowing up to 8 Optidrives to be connected to a single gateway.
Galvanically isolated bus electronics.
10.7.1. Installation
10.7.1.1. Overview - Module Front
LED Indicators
LED Indicators
1
1
3
3
5
5
Configuration Switches
Configuration Switches
PROFIBUS Connector
PROFIBUS Connector
Bottom View
Bottom View
PC Connector:
PC Connector:
1. GND
2. GND
3. RS232 Rx
4. RS232 Tx
5
9
6
1
Power:
1. +24 V DC
1
2. GND
2
www.invertekdrives.com
1
Online
2
Offline
3
3
Not Used
Not Used
Not Used
4
4
Fieldbus
Fieldbus
Diagnostics
Diagnostics
2
2
4
4
5
5
6
6
Subnet Status Flashing Green
Subnet Status Flashing Green
Subnet Status Flashing Green
A
A
B
B
6
6
Device Status Off
Device Status Off
Device Status Off
A
A
Set the PROFIBUS node address by using the switches as follows:
Set the PROFIBUS node address by using the switches as follows:
Node address = (switch B * 10) + (switch A * 1)
Node address = (switch B * 10) + (switch A * 1)
B
B
DB9
DB9
1
1
+5V
+5V
2
2
RS232 Rx (Not Used)
RS232 Rx (Not Used)
3
RS232 Tx (Not Used)
1
4
NC
4
5
Signal 0V
6
RS422 Rx+ (Not Used)
7
RS422 Rx- (Not Used)
8
RS485+ Modbus RTU
9
RS485- Modbus RTU
Power
1
+24VDC, 300mA
2
0V
Green
Online
Off
Not Online
Red
Offline
Off
Not Offline
-
-
-
-
-
Off
Off
No diagnostics present
No diagnostics present
Red, Flashing 1Hz
Red, Flashing 1Hz
Red, Flashing 1Hz
Configuration Error
Configuration Error
Configuration Error
Red, Flashing 2Hz
Red, Flashing 2Hz
Red, Flashing 2Hz
User parameter data error
User parameter data error
User parameter data error
Red, Flashing 4Hz
Red, Flashing 4Hz
Red, Flashing 4Hz
Initialisation Error
Initialisation Error
Initialisation Error
Running, but one or more transaction errors
Running, but one or more transaction errors
Green
Green
Running
Running
Red
Red
Transaction error / subnet stopped
Transaction error / subnet stopped
Power Off
Power Off
Alternating Red / Green
Alternating Red / Green
Alternating Red / Green
Invalid / missing configuration
Invalid / missing configuration
Invalid / missing configuration
Green
Green
Initialising
Initialising
Flashing Green
Flashing Green
Running
Running
Red
Red
Bootloader Mode
Bootloader Mode
Flashing Red
Flashing Red
Diagnostic Code
Diagnostic Code
Switch A
Switch A
Example:
Example:
Setting node address 42
Setting node address 42
Switch B
Switch B
Profibus Connector
Profibus Connector
Profibus Connector
Profibus Connector
5 Female 1
5
Female
9
6
Version 1.02 | Fieldbus Guide | 51
2
2
4
4
Pin no
Pin no
Pin no
Pin no
Description
Description
Description
Description
1
1
Shield
Shield
3
3
B-line
B-line
1
4
RTS
5
GND bus
6
+5V bus out
8
A-line
2, 7, 9
NC
10