5.4. PDO Default Mapping
Objects
No.
1
2
RX
PDO1
3
4
1
2
TX
PDO1
3
4
1
2
2
2
2
RX
RX
PDO2
PDO2
3
3
3
3
4
4
4
4
1
1
1
1
1
2
2
2
2
2
TX
TX
PDO2
PDO2
3
3
3
3
3
4
4
4
4
4
5.5. PDO Transmission Type
5.5. PDO Transmission Type
Various transmission modes can be selected for each PDO. For RX PDO, the following modes are supported:
Various transmission modes can be selected for each PDO. For RX PDO, the following modes are supported:
Transmission Type
Transmission Type
Transmission Type
0 – 240
0 – 240
254, 255
254, 255
254, 255
254, 255
For TX PDO, the following modes are supported:
For TX PDO, the following modes are supported:
Transmission Type
Transmission Type
Transmission Type
0
0
1-240
1-240
1-240
5
254
254
255
255
5.6. CAN Specific Object Table
5.6. CAN Specific Object Table
Index
Sub Index
1000h
0
1001h
0
1002h
0
1005h
0
1008h
0
1009h
0
100Ah
0
100Ch
0
100Dh
0
1014h
0
1015h
0
12 | Fieldbus Guide | Version 1.02
Mapped
Length
Object
2000h
Unsigned 16
2001h
Integer 16
2003h
Unsigned 16
0006h
Unsigned 16
200Ah
Unsigned 16
200Bh
Integer 16
200Dh
Unsigned 16
2010h
Integer 16
0006h
Unsigned 16
0006h
0006h
0006h
0006h
Unsigned 16
Unsigned 16
Unsigned 16
Unsigned 16
0006h
0006h
0006h
0006h
Unsigned 16
Unsigned 16
Unsigned 16
Unsigned 16
0006h
0006h
0006h
0006h
Unsigned 16
Unsigned 16
Unsigned 16
Unsigned 16
201 1h
201 1h
201 1h
201 1h
201 1h
Unsigned 16
Unsigned 16
Unsigned 16
Unsigned 16
Unsigned 16
2012h
2012h
2012h
2012h
2012h
Unsigned 16
Unsigned 16
Unsigned 16
Unsigned 16
Unsigned 16
2013h
2013h
2013h
2013h
2013h
Integer 16
Integer 16
Integer 16
Integer 16
Integer 16
2014h
2014h
2014h
2014h
2014h
Integer 16
Integer 16
Integer 16
Integer 16
Integer 16
Mode
Mode
Mode
The received data will be transferred to the drive active control register when the next sync
The received data will be transferred to the drive active control register when the next sync
Synchronous
Synchronous
message is received.
message is received.
Asynchronous
Asynchronous
Asynchronous
Asynchronous
The received data will be transferred to the drive active control register immediately without delay.
The received data will be transferred to the drive active control register immediately without delay.
The received data will be transferred to the drive active control register immediately without delay.
The received data will be transferred to the drive active control register immediately without delay.
Mode
Mode
Mode
TX PDO will only be sent out if the PDO data has changed and PDO will be transmitted on
TX PDO will only be sent out if the PDO data has changed and PDO will be transmitted on
Acyclic synchronous
Acyclic synchronous
reception of SYNC object.
reception of SYNC object.
TX PDO will be transmitted synchronously and cyclically. The transmission type indicates the
TX PDO will be transmitted synchronously and cyclically. The transmission type indicates the
Cyclic synchronous
Cyclic synchronous
Cyclic synchronous
number of SYNC object that are.
number of SYNC object that are.
Asynchronous
Asynchronous
Asynchronous
TX PDO will only be transferred once corresponding RX PDO has been received.
TX PDO will only be transferred once corresponding RX PDO has been received.
TX PDO will only be transferred once corresponding RX PDO has been received.
Asynchronous
Asynchronous
Asynchronous
TX PDO will only be transferred anytime if PDO data value has changed.
TX PDO will only be transferred anytime if PDO data value has changed.
TX PDO will only be transferred anytime if PDO data value has changed.
Function
Device Type
Error Register
Manufacturer Status Register
COB-ID Sync
Manufacturer Device Name
Manufacturer Hardware Version
Manufacturer Software Version
Guard Time (1ms)
Lifetime Factor
COB-ID EMCY
Inhibit Time Emergency (100µs)
Mapped Function
Transmission Type
Control word
Frequency setpoint
Valid immediately
User ramp reference
Dummy
Drive status register
Motor speed Hz
Send after receiving
Motor current
Drive temperature
Dummy
Dummy
Dummy
Dummy
Dummy
Dummy
Dummy
DC bus voltage
DC bus voltage
DC bus voltage
DC bus voltage
DC bus voltage
Digital input status
Digital input status
Digital input status
Digital input status
Digital input status
Analog input 1 (%)
Analog input 1 (%)
Analog input 1 (%)
Analog input 1 (%)
Analog input 1 (%)
Analog input 2 (%)
Analog input 2 (%)
Analog input 2 (%)
Analog input 2 (%)
Analog input 2 (%)
Description
Description
Description
Description
Access
Type
RO
U32
RO
U8
RO
U16
RW
U32
RO
String
RO
String
RO
String
RW
U16
RW
U8
RW
U32
RW
U16
For information
on the values
Refer to section 1 1. 1 .
254
Control Registers on
page 54
254
Refer to section 1 1. 1 . 1 .
Drive Control Word
PDO0 on page 54
RX PDO 1
254
254
254
254
PDO Map
Default Value
N
0
N
0
N
0
N
00000080h
N
ODE3
N
x.xx
N
x.xx
N
0
N
0
N
00000080h+Node ID
N
0
www.invertekdrives.com