Horizontal System

Introductory on how to set the horizontal system of the handheld oscilloscope.
Horizontal Scale
Press the Horizontal Scale button on the front panel to adjust the horizontal time base.
Press the ns to decrease the horizontal time scale and press the s to increase.
The time base information at the upper left corner of the screen will change accordingly
during the adjustment. The range of the T3DSOH1000/ T3DSOH1000-ISO horizontal
scale is from 1ns/div to 100s/div.
The Horizontal Scale button works (in the Normal time mode) while acquisitions are
running or when they are stopped. When in run mode, adjust the horizontal scale knob
to change the sample rate. When stopped, adjust the horizontal scale knob to zoom in
the acquired data.
Horizontal Delay
Press the Horizontal Position button on the front panel, the trigger point (solid inverted
triangle) will move horizontally. The trigger point moves horizontally to the right when
press > , while moves to left when press < . Press the Shift and Horizontal Position
button to reset the trigger delay.
When changing the horizontal delay, the delay time displayed in the information bar at
the top of the screen changes in real time, indicating the distance between the time
reference point and the trigger point. The available delay range depends on the selected
time/div and memory depth.