Table 9 Schedule Screen Color Identification
Color
Green
Yellow
Red
Gray
Set Schedule Times
Times are set using a 24-hour clock. Several on and off
times can be set each day.
1. On the Schedule screen (in the Setup screens), set
the ON times for each day of the week
2. Set the off times for each day of the week.
3. Set the setback times for each day of the week.
Enable Schedule Function
The Schedule function is automatically enabled when
values are entered in the Schedule screen. To disable a
scheduled event, navigate to the event and press
The event will appear gray on the screen when it is
disabled. To re-enable an event, navigate to the event
and press
.
The event will appear red (system off), yellow (system
setback), or green (system on). If no events are needed,
turn the Main Power Switch OFF to prevent system
from automatically enabling and disabling the heaters.
334130W
Description
System on
Setback
System off
Disabled
Use the Schedule Function
At the end of the work day leave the Main Power Switch
ON. The Schedule function will automatically enable
and disable the heaters and Pump at the specified
times.

Change Drums

To prevent serious burns from dripping material,
never reach under the Heated Platen after the Platen
is out of the drum.
Moving parts can pinch or amputate fingers, or can
crush feet. When the Pump is running, and when
raising or lowering the Ram, keep fingers and hands
away from the Pump intake, Platen, and lip of the
drum. When lowering the Platen to the baseplate,
keep feet away from the Platen.
Perform the following procedure to change the drum on
a fully heated system.
Be sure to reload the empty supply unit with a full
drum of material immediately. Do not raise the Ram
and remove the Platen from the empty drum until you
are ready to immediately install a new drum.
Do not raise the Ram and remove the Platen from
the empty drum unless the supply unit is at full
.
operating temperature. Drum changes can only be
performed when the system is heated.
An empty drum clamp can interfere with the up
and down operation of the Ram. When raising or
lowering the Ram, make sure the drum clamp stays
clear of the Platen assembly.
Do not use a drum of material that has been
dented or otherwise damaged; damage to the
Platen wipers can result.
Operation