Mechanical Setup - Graco Therm-O-Flow 200 Instructions-Parts List Manual

Hide thumbs Also See for Therm-O-Flow 200:
Table of Contents

Advertisement

Setup

Mechanical Setup

1. Fill displacement Pump wet cup 2/3 full with Graco
Throat Seal Liquid (TSL™) for Butyl and PSA
materials.
NOTE: Use IsoGuard Select
for PUR or reactive Polyurethane material. IGS is
designed to dissolve and suspend the Polyurethane
materials. IGS will solidify after a period of time and
should be replaced once the solidified lube does not
return to liquid form after heating.
F
. 7: Wetcup
IG
2. Turn all air regulators to their full counterclockwise
position. See Integrated Air Controls, page 9.
3. Connect a 1/2 in. (13 mm) air line from an air source
to the system air inlet (H), capable of delivering a
16
®
(IGS) (part no. 24F516)
minimum of 25-50 cfm at 100 psi (0.7 MPa, 7.0
bar). Do not use quick disconnects.
F
. 8: Air Connection
IG
4. Ensure Drum Low and Empty Sensors (C) are
mounted as shown.
NOTE: The Drum Low and Empty Sensors are used to
indicate that a drum is empty. The kit contains a sensor
mounting bracket (A), activator (B), sensors (C1, C2),
and a cable for connecting the panel inside the
Electrical Enclosure.
A
C1
C2
H
B
334130W