Setup

Grounding

Ground the unit as instructed here and in the
component manuals.
The equipment must be grounded to reduce the risk
of static sparking and electric shock. Electric or static
sparking can cause fumes to ignite or explode.
Improper grounding can cause electric shock.
Grounding provides and escape path for the electric
current.
System: ground through ground lug in Electrical
Enclosure. See Connect Power, page 19.
Air and Fluid Hoses: use only electrically conductive
hoses.
Air compressor: follow manufacturer's
recommendations.
Spray gun / Dispense valve: ground through
connection to a properly grounded fluid hose and
Pump.
F
. 13
IG
20
Material drums: follow local code. Use only metal
drums placed on a grounded surface. Do not place the
drum on a nonconductive surface, such as paper or
cardboard, which interrupts the grounding continuity
To maintain grounding continuity when flushing or
relieving pressure: follow instructions in your separate
gun manual for instructions on how to safely ground
your gun while flushing.

Connect Secondary System

A secondary system is a Therm-O-Flow supply system
that connects to the primary Therm-O-Flow system,
with the ADM. See Models, page 7 for secondary
system model numbers.
1. Connect adapter cable (AC) and communication
cable (SC) to the secondary Electrical Enclosure
and rout to splitter (SS) installed on the primary
system.
2. To enable a secondary system, select "Enable
Tandem System" on the System 1 screen. See
Select ADM Settings, page 23.
AC
SC
SS
334130W