Start­up
6.3 Description of OSD menu
Main menu
34
Function
Adjustment /
setting range
Video/PIP setting
PIP size
Off
1
2
3
Default: Off
PIP source
Auto
VGA
DVI Digital
Composite
S-Video
DVI Analog (for
SCD19102)
SoG / H / V (for
SMD19102)
Default: Auto
PIP horizontal po-
Slider control
sition
PIP vertical posi-
Slider control
tion
Brightness
0 ... 100 %
Contrast
0 ... 100 %
Description
Activating and deactivating the PIP
window and setting the PIP window
size
The source is selected that is to
be shown in the PIP window.
"VGA" and "DVI" or "SoG / H / V-
" (SMD 19102) cannot be displayed
simultaneously.
Note: When an RGB signal is dis-
played in the PIP window, resolu-
tions of up to 1280 x 1024 can be
displayed in PIP size 3 and 800 x-
 600 in PIP size 2.
The PIP window remains black if the
signal cannot be displayed.
To display the signal:
Reduce the resolution of the sig-
nal
or
Change the window size under
"PIP size"
Shift the PIP window in the horizon-
tal direction
Shift the PIP window in the vertical
direction
Set the brightness of the PIP win-
dow
Adapting the representation of
darker picture areas.
Note: The brightness settings are
already optimized for digital DVI sig-
nals. Manual changes to these val-
ues are not recommended, as this
can result in an impairment of pic-
ture quality (loss of gray scales).
Set the contrast of the PIP win-
dow
Adapting the representation of
brighter picture areas.
Note: The contrast settings are al-
ready optimized for digital DVI sig-
nals. Manual changes to these val-
ues are not recommended, as this
can result in an impairment of pic-
ture quality (loss of gray scales).