Eizo SCD 19102 Instructions For Use Manual page 30

1.3 mp 19" lcd monitor
Hide thumbs Also See for SCD 19102:
Table of Contents

Advertisement

Start­up
6.3 Description of OSD menu
Main menu
30
Function
Adjustment /
setting range
1, 2, 3, User
Color
(SCD 19102 only)
1: 9300° K
2: 7300° K
3: 6500° K (na-
tive)
User factory set-
ting: "6500° K
(native)".
This color can be
set by the user)
Default: 1
(6500°K)
User color
Define user color temperature
(SCD 19102 only)
The color setting defined here can be subsequently se-
lected using the color function (selection "User").
Note: If the color location setting is corrected with
"User Color", some color levels may be lost.
 Red color temp.
-32 ... +32
 Green color
-32 ... +32
temp.
 Blue color temp.
-32 ... +32
Description
Set the desired color temperature
or hue
Three fixed color temperatures and
one adjustable color temperature
can be selected.
Color locations 1 and 3 cannot be
saved. They only remain active
while the timing is applied.
Note: The user color setting can be
changed when "User" is selected.
Select red component of display
Select green component of display
Select blue component of display
SCD 19102 / SMD 19102
Instructions for Use, 08/2015