Eizo SCD 19102 Instruction Manual

Eizo SCD 19102 Instruction Manual

High-end 19" color and gray scale flat panel display
Hide thumbs Also See for SCD 19102:
Table of Contents

Advertisement

Quick Links

display
SOLUTIONS
SOLUTIONS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SCD 19102 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Eizo SCD 19102

  • Page 1 display SOLUTIONS SOLUTIONS...
  • Page 3 ___________________ SCD 19102 / SMD 19102 Introduction ___________________ Safety notes ___________________ Description LC displays for medical applications ___________________ Application planning High-End 19" Color and ___________________ Gray Scale Flat Panel Display Assembly SCD 19102 / SMD 19102 ___________________ Connecting Instruction Manual...
  • Page 4 Note the following: WARNING EIZO products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by EIZO. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 5: Table Of Contents

    Connector panel...........................26 Connecting the signal cables .......................27 DIP switches (for SMD 19102 only) .....................28 Connecting the line cord ......................29 Installing/removing the display stand and cable for the SCD 19102 ...........30 Serial interface ..........................34 Commissioning ............................37 Switching on the display ......................37 Operator controls .........................37...
  • Page 6 View from above ......................... 97 12.2 SCD / SMD 19102 D (with stand) ....................98 12.2.1 Front view............................ 98 12.2.2 View from left ..........................99 12.2.3 View from above ........................100 SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 7 Warranty.............................106 Repairs............................106 Environmental protection ......................106 Accessory devices ........................107 Contact............................107 Trademarks ..........................107 China RoHS (Restriction of Hazardous Substances) ..............108 Disposal of materials containing mercury ..................110 List of abbreviations/acronyms ......................113 Index..............................115 SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 8 Table of contents SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 9: Introduction

    The displays are available in color and monochrome variants: Color flat panel display ● SCD 19102 C, version without protective front pane, without multi-functional stand ● SCD 19102 CP, version with protective front pane, IPx2 at front ● SCD 19102 D, version without protective front pane, with multi-functional stand Gray scale flat panel display ●...
  • Page 10: Program For Changing The Display Settings

    The SMfit Total Care program is a web-based application and is included in the software and documentation CD shipped with each display. The software is also available as a free download on the EIZO Display Technologies website. The SMfit Total Care software also has extensive calibration functions. To use these, you will need a photometer and an activation code.
  • Page 11: Safety Notes

    Flawless, safe and reliable operation of the equipment assumes that it has been professionally transported, stored, mounted and installed as well as careful operator control and service. The units may only be used for applications for which monitors are normally used. SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 12 There must be no contact to a patient when handling the connection cables. Overload Do not connect too many devices to one socket or extension cable since this could result in a fire or electric shock. Observe the information provided by the manufacturer. SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 13 Please ensure that all steps are taken to avoid injuries or incorrect diagnoses. If your application or local regulations require calibration, EIZO offers the optional QA software "SMfit Total Care" to facilitate quality control and review activities. Observe all regulations of the country in which the display is used.
  • Page 14 Absolutely avoid scratches, shocks etc. • Remove water drops immediately; extended contact with water discolors the surface. • Clean the screen and the housing using only the cleaning agents referred to in the instruction manual. SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 15 Installation site (Page 19) General connection information (Page 23) Connecting the signal cables (Page 27) Connecting the line cord (Page 29) Serial interface (Page 34) Cleaning (Page 85) Safety specifications (Page 94) SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 16: Product-Specific Safety Notes

    EN 60601 standard. See also Mounting of unit (Page 21) Installing/removing the display stand and cable for the SCD 19102 (Page 30) SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 17: Description

    Landscape, desktop, with multifunctional stand have been specially designed for medical diagnostics according to the safety standard IEC 601. The displays comply with the safety standards UL 2601 and EN 60601-1. SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 18: Important Features

    (IPS) technology). The optimum picture resolution is 1280 x 1024 pixels. Video signals with other resolutions, as are common in medical technology, are enlarged or reduced to fit the screen size. Alternatively, they can be displayed in their original size (1:1). SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 19 In portrait mode, the keypad is positioned at the top right and the OSD is not rotated (i.e. the OSD inscription "Dynamic help for keypad function" is still positioned above the keys). SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 20 Description 3.3 Important features SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 21: Application Planning

    The display should be positioned so that reflections of lights, windows, furniture with shiny surfaces or light-colored walls do not appear on the screen. In order to reduce mirroring on the unit, only use non-dazzling reflector lights for the ceiling lighting. SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 22 The unit should not be switched on until all the condensed water has evaporated, including that inside the unit. This may take several hours, depending on the conditions. See also Cleaning (Page 85) SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 23: Assembly

    Max. 3 Nm Figure 5-1 Insertion depth of mounting screws See also Product-specific safety notes (Page 14) Installation site (Page 19) Installing/removing the display stand and cable for the SCD 19102 (Page 30) SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 24 Assembly 5.1 Mounting of unit SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 25: Connecting

    • Screw tight or lock all plug-in connections. • Signal and power cables must not be routed through the same duct. • The display must not share a power supply with motors or valves (interference peaks!). SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 26: Connector Location

    The connectors are located within the connection compartment under the cover on the rear of the display. The power switch is not covered and is freely accessible. Figure 6-1 Rear view of SCD / SMD 19102 SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 27: Summary Of Signals And Connections

    Connecting 6.3 Summary of signals and connections Summary of signals and connections SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 28: Connector Panel

    A connection panel for the signals and power supply is located at the rear of the flat panel display. SCD 19102 Figure 6-2 Connection panel of the SCD 19102 high-end color flat panel display. SMD 19102 Figure 6-3 Connection panel of the SMD 19102 high-end gray scale flat panel display...
  • Page 29: Connecting The Signal Cables

    The DVI cable can be connected in two manners: ● With DVI digital signal or ● With DVI analog signal (SCD 19102 only) BNC sockets (SoG / H / V) ● With a wire (R or G or B, with composite synchronization): –...
  • Page 30: Dip Switches (For Smd 19102 Only)

    (75 Ω) for the H and V synchronization inputs. Figure 6-4 Position of the DIP switches Delivery state Switch Function Delivery state Input resistance for H/H+V signal 75 Ω Input resistance for V signal 75 Ω SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 31: Connecting The Line Cord

    • Note for North America: Molded power supply plugs must comply with the requirements for hospitals with respect to CSA Std. C22.2 No. 21 and UL 498. See also Connector panel (Page 26) General safety notes (Page 9) SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 32: Installing/Removing The Display Stand And Cable For The Scd 19102

    Connecting 6.8 Installing/removing the display stand and cable for the SCD 19102 Installing/removing the display stand and cable for the SCD 19102 CAUTION Do not use screws of excessive length Screws which are too long can damage mechanical and electronic components of the unit.
  • Page 33 Connecting 6.8 Installing/removing the display stand and cable for the SCD 19102 6. First tighten the top two screws. 7. Then rotate the display slightly, and tighten the bottom screws. 8. Lay the connecting cable in the cable duct. SCD 19102 / SMD 19102...
  • Page 34 Connecting 6.8 Installing/removing the display stand and cable for the SCD 19102 9. Then fit the cable duct cover or press it down. CAUTION Do not route the cable too tightly in the cable duct When the display is rotated about its axis, the connecting cable could be broken or trapped.
  • Page 35 Connecting 6.8 Installing/removing the display stand and cable for the SCD 19102 Completely assembled display stand See also Mounting of unit (Page 21) Product-specific safety notes (Page 14) SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 36: Serial Interface

    Please note the diagram for the "6-pin mini-DIN socket": It shows the lower left corner of the underside of the display (viewed from rear). Figure 6-5 Service socket for measuring instruments SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 37 6.9 Serial interface Figure 6-6 Possible configuration – serial bus mode * Photometer is a generic term for the measuring instruments suggested by EIZO GmbH Display Technologies: ● Universal Serial Luminance Meter with adapter from 9-contact Sub-D to 6-contact mini- DIN socket **) ●...
  • Page 38 Connecting 6.9 Serial interface SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 39: Commissioning

    The four buttons and the status LED are located on the front in the bottom right-hand corner of the display . The status LED is lit when power is supplied to the device and the power switch is set to On. SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 40: Description Of Osd Menu

    The OSD menu is used to make settings for operation of the flat panel display with a source. The OSD can also be operated without an input signal to a limited extent. SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 41 Commissioning 7.3 Description of OSD menu See also Exit OSD (Page 52) Menu functions (Page 40) Servicelevel 2 functions (Page 53) Lock/unlock OSD menu (Page 60) SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 42: Menu Functions

    The contrast settings are already optimized for digital DVI signals. Manual changes to these values are not recommended, as this can result in an impairment of picture quality (loss of gray scales). SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 43 Shift picture in horizontal analog picture signal) direction With identical display and graphics card settings, the complete picture to be displayed fills the display area of the monitor with the exact number of pixels. SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 44 Alternatively, the source can DVI Analog be selected through a hot key function (see the OSD menu → Others → SMD 19102: OSD setting). DVI Digital Composite S-Video SoG / H / V SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 45 Language German, English Use the "Language" menu to select the language of the Default: English OSD menu German or English can be selected. English is the delivery default setting. SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 46 "Pixel On/Off" test pattern is displayed. Video setting (only for video signals) Saturation 1 … 255 Adjusting the saturation for (only SCD 19102 for video video signals Default: 128 signals) SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 47 Filter No. 1 produces the "sharpest" picture, as it does the least filtering. Filter No. 5 filters the most; the greatest danger exists with this filter that details can no longer be recognized. SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 48 The brightness settings are already optimized for digital DVI signals. Manual changes to these values are not recommended, as this can result in an impairment of picture quality (loss of gray scales). SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 49 (loss of gray scales). PIP advanced settings Saturation 1 … 255 Adjusting the saturation for (only SCD 19102 for video video signals displayed in Default: 128 signals) PIP sharpness 1 ... 5 One of 5 filters can be...
  • Page 50 Default: Inactive If "Active" is selected, the PIP window can be opened or closed with the saved settings using button 4 on the front without opening the OSD menu. SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 51 SCD 19102: LUT 1 For further details on LUT settings, see "Display adjustment – LUT" (Page 64). The LUTs that can be selected are displayed in the table in the OSD menu. SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 52 If a monochrome signal Default: • arrives, it is green on the (for SCD19102) • color display. Monochrome (for • To obtain correct b/w • SMD19102 images, set the "Signal" parameter to monochrome. SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 53 The A/D converters have already been factory-set and need not be readjusted. DVI enhancer Enhances the DVI-D signal quality over long distances, even when standard cable is used SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 54: Exit Osd

    Note: If the OSD menu is exited by changing the timing or switching off the monitor, the changes made are saved. See also Servicelevel 2 functions (Page 53) SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 55: Servicelevel 2 Functions

    7.3 Description of OSD menu 7.3.4 Servicelevel 2 functions CAUTION Only servicing personnel trained by EIZO GmbH Display Technologies have access to "Servicelevel 2. The "Servicelevel 2" menu can be accessed from the OSD main menu. Key combination for opening "Servicelevel 2"...
  • Page 56 Note The data is only displayed when the panel has warmed up (after approx. 20 min). The display value only serves for information purposes. SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 57 The 5-digit combination indicates which individual memory addresses have been allocated. Example: 10010 ⇒ Addresses 1 and 4 have been allocated. Reset custom settings Execute Clears the content of the five memory locations SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 58 All the pixels on the • display area are activated (exception: The first column on the left of the panel remains black). Test of columns or line driver SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 59 Serial interface The serial interface can be activated or deactivated. If the serial interface is Default: On deactivated ("Off"), it is possible to suppress e.g. the downloading of firmware. SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 60 (progressive) of up to 60 Hz connected to the "VGA" and "DVI Analog" signal inputs. Note: See Chapter "Motion image improvement" (Page 80) SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 61 For SCD 19102: Information Display operating hours Operation time above 160 cd counter over 160 Cd/m² for SCD 19102 and 400 Cd/m² For SMD 19102: for SMD19102 Operation time above 400 cd For SCD 19102: Information...
  • Page 62: Lock/Unlock Osd Menu

    To achieve optimum picture quality, the display must be operated with a graphics resolution of 1280 x 1024 pixels. The corresponding setting for the graphics card must be made in the operating system. SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 63: Avoiding Image Sticking

    • The digital input (DVI-D) does not require a fine adjustment since the signal display is always optimum. With a fine adjustment, it is possible that gray scales are not displayed. SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 64: Adaptation Of Display - Video Source / Graphics Card

    Please note that the calibration (in the look up table) is not affected by these settings (EIZO GmbH Display Technologies displays are factory-calibrated and retain these settings):...
  • Page 65 Please note that a permanently higher setting for the backlighting results in a more rapid reduction in the brightness performance toward the end of the service life. See also Menu functions (Page 40) SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 66: Display Adjustment - Lut

    You can choose between five different LUT values in this menu. The values saved in the display are shown in a table in the OSD window. Note For further details, see the SMfit Total Care operating instructions. See also Menu functions (Page 40) SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 67: Display Adjustment - Force Mode

    Force Mode NOTICE "Force Mode" is an engineering tool Force Mode is only used to determine exotic and unknown timings. Using these data, an unknown timing can be implemented in the monitor. SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 68: Foreword (A Number Of Useful Points To Facilitate Understanding Of Timing And The Various Types Of Timing)

    Field 1 consists of the lines 1 to 262 1/2, and field 2 of the lines 262 1/2 to 525. Only a few lines are displayed at the top and bottom of each field. Figure 7-4 Interlaced scanning system SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 69 A non-interlaced image is output on the screen in that all horizontal lines are scanned from top to bottom in one scan. Horizontal timing diagram (the vertical timing diagram is identical) Figure 7-6 Timing diagram SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 70: Name Equivalence For The Force Mode Menu

    Timings whose setting values are unknown can be set step-by-step in Live mode using test patterns. The changes in the test pattern are output live on the display. See "Live mode" (Page 72). Figure 7-8 Live mode menu SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 71: Blind Mode

    2. Open the Blind mode" menu: Main menu → Servicelevel 2 → Force Mode → Blind mode. 3. Enter the timing data into the individual input fields using the Menu, Up and Down buttons. SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 72 For progressive timings with an image refresh rate greater than 60 Hz, only the item "For static pictures" or "Reset" can be selected in line 6 in the "Blind mode" menu. SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 73 Commissioning 7.4 System settings NOTICE If the "Reset" setting is selected, all learned values are deactivated in the current Force Mode window. SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 74: Live Mode

    Sequence for setting a timing 1. Determine start values using autofunction 2. Optimize scanning frequency 3. Optimize geometry and resolution Step-by-step instructions for setting a timing can be found in the next three sections. SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 75 For progressive timings with an image refresh rate greater than 60 Hz, only the item "For static pictures" or "Reset" can be selected in line 6 in the "Live mode" menu. SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 76 If the interval between the interferences becomes larger, and these therefore also become fewer, you are moving the slider in the correct direction. SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 77 "For static pictures" or "For motion pictures". The current setting is then saved, and the slider set to the center of the control range. Once you have set the signal frequency optimally, you can continue with the description. SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 78 "Reset" can be selected in line 6 in the "Live mode" menu. NOTICE If the "Reset" setting is selected, all learned values are deactivated in the current Force Mode window. SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 79 Note Gray/blue area not visible If no gray/blue area is visible on the left and right sides of the image, reduce the "Horizontal resolution" until the gray/blue area becomes visible. SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 80 Once all settings have been carried out in Force Mode, the desired zoom factor can be selected from the "Position/Zoom" menu. Further use of determined values The values determined step-by-step using "Live mode" can now be copied and entered directly in further displays using "Blind mode". SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 81 1. Up to five timings can be saved in "User / Custom settings". Save the timings in the OSD menu "Servicelevel 2 → User / Custom settings". 2. Select memory location using "Custom settings number". SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 82: Motion Image Improvement With Interlaced And Non-Interlaced (Progressive)

    ● If the motion image improvement is to be activated, the setting for this must be changed from "Inactive" to "Active" either in the "Servicelevel 2" → "Others" menu or in the Force Mode menu "Blind mode" or "Live mode". SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 83 "S-Video" and "Composite Video". The staircase signals can occur if a signal source with motion image improvement is active in the main picture. See also Servicelevel 2 functions (Page 53) Blind mode (Page 69) Live mode (Page 72) SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 84 Commissioning 7.4 System settings SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 85: Operation

    Following commissioning, operation is limited to switching on and off. ● Switch on the device using the power switch. The green operation LED now lights up permanently. See also Troubleshooting (Page 87) SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 86 Operation 8.2 Switching on the display SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 87: Service And Maintenance

    Isopropyl alcohol (70%) Mikrozid liquid • • 0.5% chlorhexidine in • isopropyl alcohol (70%) Aldehyde Melsitt Aldasan 2000 • • Cidex Kohsolin • • Cidex (2.4% glutaraldehyde Gigasept FF • • solution) SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 88 Forbidden cleaning agents and disinfectants Agent class Tested cleaning agents and disinfectants: Peroxide compounds Perform Dismozon pur These cleaning agents and disinfectants can bleach the paint after a longer period of application. SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 89: Troubleshooting

    In the OSD menu, switch over transmitting a green signal from "RGB" to "MONO" The image cannot be shifted Synchronization not OK Set maximum window size and horizontally with reference to the perform "Auto adjust" panel SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 90 Troubleshooting Other information output via two-color LEDs Display status LED orange No fault; "Power down" was switched on and activated LED green Video signal recognized, no fault SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 91: Technical Specifications

    6 CCFT (cold cathode fluorescent tubes) Lifetime of backlight Typically 45,000 hours for CCFT (applies to an ambient temperature for the backlight of 25 °C) See also Menu functions (Page 40) SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 92: Voltage Supply

    - the color hues for color images - are also reduced and may be visible). Timing recognition H frequency, V frequency, interlaced, number of horizontal lines SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 93: Inputs/Outputs

    Analog signal output SoG signal Video level: 0.5 ... 1.0 V • Sync level: 0.2 ... 0.3 V • Serial interface RS 232 via RJ 11 socket (female) or 6-pin mini-DIN socket SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 94: Control And Connection Elements

    SCD / SMD 19102 CP (without stand, with • front pane) 314 x 348.4 ... 546.5 x 279 * SCD / SMD 19102 D (without stand) • * Corresponds to a possible height adjustment of 100 mm. SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 95: Climatic Conditions

    5 ... 9 Hz at ± 3.5 mm deflection 9 ... 500 Hz at 10 m/s² Shock To EN 60068-2-27 (single impact) 250 m/s², 6 ms (in storage packaging) to EN 60068-2-29 (continuous shocks) SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 96: Safety Specifications

    Noise immunity EN 61000-4-6 150 kHz ... 80 MHz 3 V/m 80 % AM 1 kHz Magnetic constant fields EN 61000-4-8 Max. 4000 A/m Magnetic alternating fields EN 61000-4-8 Max. 10 A/m SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 97: Dimensional Drawings

    Dimensional drawings All dimensions in mm 12.1 SCD / SMD 19102 C/CP (without stand) 12.1.1 Front view SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 98: View From Left

    Dimensional drawings 12.1 SCD / SMD 19102 C/CP (without stand) 12.1.2 View from left SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 99: Rear View

    Dimensional drawings 12.1 SCD / SMD 19102 C/CP (without stand) 12.1.3 Rear view 12.1.4 View from above SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 100: Scd / Smd 19102 D (With Stand)

    Dimensional drawings 12.2 SCD / SMD 19102 D (with stand) 12.2 SCD / SMD 19102 D (with stand) 12.2.1 Front view SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 101: View From Left

    Dimensional drawings 12.2 SCD / SMD 19102 D (with stand) 12.2.2 View from left SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 102: View From Above

    Dimensional drawings 12.2 SCD / SMD 19102 D (with stand) 12.2.3 View from above SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 103: Accessories

    DVI transmission path. Digital graphics connection supports the transmission of high-quality video data. Using the DVI cable set from EIZO, this data can be transmitted over a distance of up to 36 m without any reduction in quality. The transmission set comprises a receiver and a transmitter that are connected over the CAT cable.
  • Page 104 Different cables and adapters allow problem-free integration of our displays, even in extremely complex systems. Product Order No. PS2 adapter for luminance meter 6GF6980-1TB03 DVI cable, single link, 3 m 6GF6980-1TA07 BNC to VGA cable 6GF6980-1TB04 UMC-201, USB serial converter 6GF6980-8WG15 SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 105: Calibration Tools

    6GF6980-7DB11 13.4 Graphics cards EIZO Display Controller cards are part of our strategy of supplying everything from a single source. These cards have been tested with the display and the quality assurance software SMfit Total Care. Long-term availability provides further assurance of rugged interfaces and minimal installation outlay.
  • Page 106 Accessories 13.4 Graphics cards SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 107: Appendix

    Appendix Markings and symbols on the monitor Meaning of markings and symbols on the SCD 19102/SMD 19102 Marking/symbol Description Symbol for "Caution, observe accompanying documents". Appears on the name plate. CE marking (EU conformity mark). Appears on the name plate.
  • Page 108: Warranty

    Repairs Please contact the sales partner from whom you purchased the product. Environmental protection Please observe all local requirements and laws pertaining to the disposal of displays. SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 109: Accessory Devices

    Support during installation and for technical questions Medical Monitor Solutions (http://www.eizo.eu) Trademarks The EIZO Logo is a registered trademark of EIZO NANAO CORPORATION in Japan and other countries. EIZO is a registered trademark of EIZO NANAO CORPORATION in Japan and other countries.
  • Page 110: China Rohs (Restriction Of Hazardous Substances)

    EFUP shall be done in accordance with the Product Maintenance Procedures. This product must not be disposed of as unsorted municipal waste, and must be collected separately and handled properly after decommissioning. SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 111 There is no risk, because the substance is integrated in the glass of the flat lamp.The flat lamps of the LCD Flat screen for medical backlights contain Mercury. The Mercury is inside the CCFL tubes. SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 112: Disposal Of Materials Containing Mercury

    (このシステムでは、モニターディスプレイのバックライトランプに水銀が含まれています 。) Dette produktet består av utstyr som kan inneholde kvikksølv, som må resirkuleres eller deponeres i samsvar med lokale eller nasjonale lover. (Innenfor dette systemet inneholder baklyslampene i monitordisplayet kvikksølv.) SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 113 Το συγκεκριμένο προϊόν περιλαμβάνει συσκευές που ενδέχεται να περιέχουν υδράργυρο, η ανακύκλωση ή απόρριψη του οποίου πρέπει να πραγματοποιείται σύμφωνα με τον τοπική, πολιτειακή ή εθνική νομοθεσία. (Στο συγκεκριμένο σύστημα, οι λυχνίες οπίσθιου φωτισμού στην οθόνη του μόνιτορ περιέχουν υδράργυρο) SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 114 Appendix A.9 Disposal of materials containing mercury SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 115: List Of Abbreviations/Acronyms

    Medical Device Directive On-screen display Protective Earth SMfit Total Care Display QA software SMPTE Society for Motion Picture and Television Engineers SVGA Super Video Graphics Array TN-S mains Terre Neutre–Separé Thin Film Transistor SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 116 List of abbreviations/acronyms Video Graphics Array VESA Video Electronics Standards Association Xtended Graphics Array Units of measurement: Cd/m² Candela/m² (photometric measurement for brightness) 3.426 cd/m² SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 117: Index

    Change of environment, 20 Observe EMC requirements when connecting, 23 Optimize resolution, 77 Optimum picture quality, 60 OSD menu Device Cancel locking, 60 disconnect from supply mains, 24 Digital input Fine adjustment, 61 SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 118 Sub-D socket, 27 Support During installation and for technical questions, 107 Symbols, 105 Universal Serial Luminance Meter, 35 Ventilation, 19 Video input, 91 Video inputs Mini-DIN and BNC sockets, 28 Warranty conditions, 106 SCD 19102 / SMD 19102 Instruction Manual, 10/2011, A5E01588521A-004...
  • Page 120 EIZO GmbH Display Technologies Siemensallee 84 76187 KARLSRUHE GERMANY www.eizo.eu Order No.: A5E01588521A-004...

This manual is also suitable for:

Smd 19102

Table of Contents