Install The New Position Sensor - Graco E-Flo EM0011 Repair Parts

Dc motor
Hide thumbs Also See for E-Flo EM0011:
Table of Contents

Advertisement

Install the New Position Sensor

1. Carefully screw the replacement position sensor
into the center housing.
NOTE: Be careful not to damage the wires. Rotate
the wires while the position sensor is installed to
prevent the wires from being twisted.
2. Use the 6 mm wrench to complete the installation of
the position sensor. Do not use excessive torque.
Stop once the position sensor bottoms out in the
bore.
NOTE: Do not over tighten the position sensor.
Damage to the position sensor may result.
3. Using your fingers, tighten the jam nut on the
position sensor.
NOTE: Do NOT use a wrench to tighten the jam nut.
Damage to the position sensor may result.
4. Plug the position sensor into the control board.
NOTE: If you are replacing an older position sensor
and the motor is Series A, use the conversion wiring
harness (see F
. 47). If the motor is Series B or later,
IG
the conversion wiring harness is unnecessary.
3A4801G
Position Sensor Replacement Kit 24W920
F
. 47: Conversion Wiring Harness
IG
45

Advertisement

Table of Contents
loading