Encoder Replacement Kit 24U938

Encoder Replacement Kit 24U938

Overview

The E-Flo DC uses the encoder for two purposes:
The encoder informs the control board where the
motor is in its mechanical rotation and uses that
information to properly control the motor torque.
The encoder controls stroke length by allowing the
control board to count the number of complete
motor rotations.

Tools Required

6 mm hex wrench
.050 in hex wrench
Phillips screwdriver (#1)
Torque wrench 15 ft-lb (20 N•m)
Blue (medium) thread locking compound

Remove the Electronics Cover

NOTICE
To avoid equipment damage, carefully support the
cover when removing the last bolt. Hold the cover
horizontally and take care that the wires are not
pulled tight.
1. Follow the instructions in Prepare for Repair,
page 16.
2. Using a 6 mm hex wrench, remove the 12 bolts that
hold the electronics cover.
40
3. Support the cover after the bolts are removed to
prevent excess strain on the wires inside the E-Flo
DC.
F
. 39: Electronics Cover
IG

Remove the Motor Cover

Using a 6 mm hex wrench, remove the four bolts (24)
and washers (43) that are securing the motor cover.
F
. 40: Motor Cover
IG

Remove the Encoder

1. Unplug the cable from the encoder (21).
2. Using the .050 in hex wrench, loosen the two hub
set screws (AA) from the sides of the encoder. Do
not remove the screws.