Prepare for Repair

Prepare for Repair
To avoid electric shock, turn off the equipment power
and shut off the power at the main circuit breaker
before installing.
1. Remove power from the motor.
2. Follow the appropriate lock-out/tag-out
procedures.
3. Follow the Pressure Relief Procedure, page 16.
4. Decouple the pump lower from the motor.
5. If you are replacing the fan coupler, fan shaft, gear
shaft, or output shaft, see
16
Drain the Oil, page
17.

Pressure Relief Procedure

Follow the Pressure Relief Procedure whenever
you see this symbol.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury
from splashing fluid and moving parts, follow the
Pressure Relief Procedure when you stop spraying
and before cleaning, checking, or servicing the
equipment.
1. Disengage the start/stop control (C). See
the Power Supply, page
2. Shut off and lock out the fused safety switch (B).
3. Relieve all fluid pressure as explained in your
separate E-Flo DC pump manual.
Connect
16.
3A4801G