4. MAINTENANCE
STEP 2)
Remove the Pump Housing while removing FOUR
(4) Hex Head Cap Screws (Pos. 1016). When the
screws are removed, the Pump Housing (Pos.
2530) can be removed. The Pump Face (Pos.
2528) does not have to be removed from the
Pump Housing.
STEP 3)
Fixate the Drive Shaft (Pos. 1000) by holding the
Drive Shaft Spindle (Pos. 2200) by hand, and
turning the Driven Shaft Spindle (Pos. 2201) to
one end with the other hand, until both spindles
touch eachother at position S20 and S40.
STEP 4)
Measure the gap position S30 with a feeler
gauge. Divide that clearance in 2. (For example,
if the clearance at S30 was 0.30mm, you will end
up with .15mm). This is known as the "half-gap"
dimension.