4. MAINTENANCE
STEP 2)
REMOVING THE PUMP HOUSING
A. Remove the FOUR (4) Hex Screws (Pos. 1016).
B. Remove the whole Pump Housing (Pos. 2530)
outwards, away from the Gear Housing, and off
of the spindles.
STEP 3)
BLOCKING THE SHAFT IN THE LANTERN AREA
Blocking the Shaft in the Lantern area prevents
the spindles from turning during maintenance
and inspection.
A. Remove both Cap Nuts (Pos. 3002) from the
Lantern Safety Guard.
B. Remove the Lantern Safety Guard (Pos. 3001).
C. Rotate spindles until the hole on Pump Coupler
(Pos. 2247) is facing up.
D. Insert Shaft Blocking Tool into top of Lantern
opening, and guide the peg into the coupler hole,
making certain that it is all the way in, and firmly
in place. Be sure that the Shaft Blocking Tool also
engages in the Lantern Window.