4. MAINTENANCE
STEP 1)
REMOVING THE PROTECTION SHIELDS
Remove both Protection Shields (Pos. 2546 & Pos.
2547) on the Seal Housing (Pos. 2188).
STEP 2)
INSTALLING BOTH SEALS INTO THE SEAL HOUSING
A. Lightly lubricate all exposed elastomers at both
mechanical seals with the delivered silicone-
based lubricant. Adding too much lubricant can
be detrimental to properly seating the O-rings.
B. Install Mechanical Seals (Pos. 2535) into the
Seal Housing (Pos. 2188), making sure that they
align with the Pin for Mechanical Seal (Pos. 2538).
C. Be sure that the Mechanical Seals are pressed
all the way into the Seal Housing, and that both
are seated evenly.
D. Lightly re-install both Hex Head Cap Screws for
Mechanical Seal (Pos. 2533) into the Seal Housing
(Pos. 2188), and hand tighten to make sure that
the seals are held in place.