4.4 Maintenance Instructions for ML-2

4.4.1 Removing the Pump Housing

Removing the Pump Housing can be done for the following reasons:
A) Sanitary Inspection
B) First action in case the pump does not pump product.
Required Tools:
• Socket Hex Nut (30mm)
• Torque Wrench (Large) for torques up to 150 Nm
STEP 1)
Remove the FOUR (4) Hex Screws (Pos. 1016).
STEP 2)
Remove the whole Pump Housing (Pos. 2530)
towards the front.
STEP 3)
Inspect the product contact surfaces for
cleanliness
STEP 4)
Inspect the product contact surfaces for scratches
and bruises.
STEP 5)
Inspect the elastomers for wear and tear, and
correct installation.