4. MAINTENANCE
STEP 7)
FIXATING THE SPINDLES
To fixate the spindles, use the Spindle Screws
(Pos. 2180) with O-rings (Pos. 2194). Add a small
amount of Blue Loctite™ to the Spindle Screw
threads to secure it. Torque both Spindle Screws
to 150 Nm.
STEP 8)
REMOVAL OF SHAFT BLOCKING TOOL
Remove the shaft blocking tool in the lantern
area.
STEP 9)
REINSTALL THE LANTERN SAFETY GUARD
Re-install the Lantern Safety Guard (Pos. 3001)
with the Cap Nuts for Lantern Safety Guard (Pos.
3002).