4. MAINTENANCE
STEP 4)
RESEATING THE MECHANICAL SEALS
Loosen both Hex Head Cap Screws (Pos. 2533)
lightly and push the Mechanical Seals (Pos. 2535)
by hand all the way to the back into the housing.
It could have been minimally shifted during the
installation.
STEP 5)
REINSTALLING THE PROTECTION SHIELDS
Re-install the TWO (2) Protection Shields (Pos.
2546 & Pos. 2547).
Page 60
PROCESSTEC INC. 2022