Procedure
1. Set the upstream breaker which provide the power to this EVSE to OFF and lock
it. Make sure that this breaker stays in the OFF position during the procedure.
2. Open the front door and the right door. Refer to section 8.1.
3. Measure the AC voltage. Refer to section 6.6.2.
4. Make sure that all the measured voltages are 0 V.
5. Measure the DC voltage. Refer to section 6.6.3.
6. Make sure that all the measured voltages are 0 V.
7. Close the doors. Refer to section 8.2.
6.6.2
Measure the AC voltage
Preliminary requirements
Procedure
1. Measure the AC voltage between the terminals on the surge protection device
switch:
•
•
•
Use the voltage tester.
6.6.3
Measure the DC voltage
Preliminary requirements
9AKK108466A3703-EN | 001
•
Owner
•
Voltage tester. Refer to
section 10.5.
L1 to L2
L1 to L3
L2 to L3
Note: The surge protection device switch shows the indications L1, L2
and L3.
•
Owner
•
Voltage tester. Refer to
section 10.5.
•
Only do this procedure if a
different procedure refers
to this procedure.
•
Only do this procedure if a
different procedure refers
to this procedure.
Operation
61