Evse Power Rating; Evse Rating During Normal Duty Operation; Evse Derating During Normal Duty Operation; Evse Rating In Heavy Duty Operation - ABB ADC-90-200-C1 Operation And Installation Manual

All-in-one 90kw dc fast charger
Table of Contents

Advertisement

Technical data
10.14

EVSE power rating

10.14.1

EVSE rating during normal duty operation

Normal duty operation applies for use in public applications with moderate traffic.
Parameter
Terra 94
Terra 104
Terra 124
Terra 184
10.14.2

EVSE derating during normal duty operation

The table shows the steady state rating of the EVSE at specific ambient
temperatures.
Parameter
Ambient temperature
[°C]
-35 ... + 35
+ 36 ... + 40
+ 41 ... + 45
+ 46 ... + 50
+ 51 ... + 55
The output power of the EVSE can be limited by the temperature of the charge
connector. This limitation can be caused by the connector model and rating, the EV
socket rating and the ambient conditions.
10.14.3

EVSE rating in heavy duty operation

Heavy duty operation applies for use in public applications with heavy traffic or
commercial/fleet applications.
Parameter
Terra 94
Terra 104
Terra 124
Terra 184
10.14.4

EVSE derating in heavy duty operation

The table shows the steady state rating of the EVSE at specific ambient
temperatures.
88
Specification [kW]
90
100
120
180
Specification
Power Output [%]
[°F]
-31 ... +95
100
+96 ...+104
90
+105 ...+113
85
+114 ...+122
75
+123 ...+131
65
Specification [kW]
75
100
100
150
De-rating [%]
0
10
15
25
35
9AKK108466A3703-EN | 001