Harmonics On The Grid; Terra 184 - ABB ADC-90-200-C1 Operation And Installation Manual

All-in-one 90kw dc fast charger
Table of Contents

Advertisement

Parameter
Ambient temperature
[°C]
-35 ... + 35
+ 36 ... + 40
+ 41 ... + 45
+ 46 ... + 50
+ 51 ... + 55
The output power of the EVSE can be limited by the temperature of the charge
connector. This limitation can be caused by the connector model and rating, the EV
socket rating and the ambient conditions.
10.15

Harmonics on the grid

10.15.1

Terra 184

Working
point
900 V /
200 A
Order
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
9AKK108466A3703-EN | 001
[°F]
-31 ... +95
+96 ...+104
+105 ...+113
+114 ...+122
+123 ...+131
Electric
V
(L1/L2/L3)
thd
load
100 %
0.669 %
0.638 %
Phase L1
IRMS
HDF
[A]
[%]
225.10
100.00
0.17
0.07
0.57
0.25
0.42
0.19
6.06
2.69
0.23
0.10
2.07
0.92
0.35
0.15
0.19
0.08
0.05
0.02
0.36
0.16
0.26
0.11
0.63
0.28
0.26
0.11
0.01
0.01
0.20
0.09
0.85
0.38
0.25
0.11
Specification
Power Output [%]
100
100
93
80
67
I
(L1/L2/L3)
thd
0.698 %
3017 %
Phase L2
IRMS
HDF
[A]
[%]
225.25
100.00
0.66
0.30
0.52
0.23
0.17
0.08
6.21
2.76
0.25
0.11
1.93
0.86
0.18
0.08
0.14
0.06
0.04
0.02
0.31
0.14
0.16
0.07
0.75
0.33
0.15
0.07
0.17
0.08
0.39
0.18
0.78
0.35
0.27
0.12
Technical data
De-rating [%]
0
0
7
20
33
3070 %
2984 %
Phase L3
IRMS
HDF
[A]
[%]
225.04
100.00
0.64
0.29
1.08
0.48
0.34
0.15
5.76
2.56
0.53
0.24
2.08
0.93
0.21
0.09
0.13
0.06
0.09
0.04
0.42
0.19
0.31
0.14
0.57
0.26
0.24
0.11
0.16
0.07
0.30
0.13
0.76
0.34
0.47
0.21
89