27. PUMP AND POOL LIGHT ON CONTROL

MyALARM2 allows pool water filter pumps to be controlled. Thanks to this application, considerable energy
savings can be achieved since the system turns on based on the previous day's average water temperature.
Furthermore, a time can be used to automatically turn pool lights on/off.
The application requires the following settings:
TEMPERATURE SENSOR WITH CURRENT OUTPUT CONNECTED TO ANALOG INPUT 1
PUMP ON/OFF CONNECTED TO RELAY OUTPUT 1
LIGHTS ON/OFF CONNECTED TO RELAY OUTPUT 2
Contact Seneca srl to purchase the temperature sensor.
ATTENTION!
The pool pump control application uses the datalogger to read the previous day's average water
temperature and thus the datalogger cannot be manually set.