2.4. Rotary Switch

There are 4 rotary switches on the I-7532RM-FD for configuring CAN1/2 arbitration and
data phase baud rate. The descriptions are as follows.
CAN1 A_BR/D_BR  CAN1 Arbitration/Data phase baud rate
CAN2 A_BR/D_BR  CAN2 Arbitration/Data phase baud rate
A_BR (Arbitration phase baud rate) is defined as follows:
Switch
Baud (bps)
Switch
Baud (bps)
D_BR (Data phase baud rate) is defined as follows:
Switch
0
Baud
CAN
(bps)
Mode
Switch
8
Baud
1M
(bps)
NOTE:
1. When the D_BR switch is "0" (CAN mode), this CAN port will be set to CAN mode,
using only the setting of the A_BR switch as the CAN baud rate and not supporting
any CAN FD messages,
2. When A_BR and D_BR switches are set to "1", the baud rate of this CAN port will be
user-defined and set by the utility.
I-7532RM-FD ( 2-port CAN/CAN FD Bridge )
Copyright © 2023 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com
0
1
2
User-defined
10k
8
9
A
125k
200k
250k
1
User-defined 100k
9
2M
2.5M
User Manual (version 1.0.0)
3
4
20k
40k
B
C
400k
500k
2
3
4
200k
250k
A
B
C
3M
4M
5
6
7
50k
80k
100k
D
E
F
600k
800k
1M
5
6
400k
500k
800k
D
E
5M
6M
10M
Page: 11
7
F