2.4 Rotary Switch

When users would like to set the CAN baud rate or message filter of
I-2533, use the rotary swich on the upper of the power connector to archieve
this purpose. Users can find it on the top of the power connector.
There are 16 sections on the rotary switch. They are descripted on the
following table.
Switch Value
0
1
2
3
4
5
6
7
8
9
A
B~D
E
F
C
Rotary switch for
CAN baud rate
Figure 2-3 Location of Rotary Switch
Table 2-2 Description of Rotary Switch
Set baud rate to 10 kbps
Set baud rate to 20 kbps
Set baud rate to 50 kbps
Set baud rate to 80 kbps
Set baud rate to 100 kbps
Set baud rate to 125 kbps
Set baud rate to 250 kbps
Set baud rate to 500 kbps
Set baud rate to 800 kbps
Set baud rate to 1 Mbps
Set baud rate to user-defined baud rate which is configured
by I-2533 utility.
Not-available
Firmware update mode.
Set I-2533 into configuration mode.
I-2533 User Manual (ver. 1.1, 2013/05/31) ------9