7800 MultiFrame Manual
7880DEC-MP2HD-2 Dual HD MPEG-2 Decoder
4.
CONFIGURING INPUTS
4.1.
INPUT MONITOR
4.1.1. Input Monitor
•
Input State: Displays either Active or Inactive, this field displays the state of the current input
(either input 1 or input 2).
•
Num Programs: This indicates the number of programs present within the stream; this is read
from the PSIP / PSI in the stream.
•
Input Bitrate: This indicates the gross bitrate of the input in bits/s.
•
Network ID: This indicates, in decimals, the Network ID. This is read from the PSIP / PSI in the
stream.
•
Network Name: This indicates the Network Name of the stream, if present. This is read from
the PSIP / PSI in the stream.
4.1.2. Input Control
•
Input Stream Mode: Options available are ATSC, DVB and MPEG.
o It is important to select the standard to which the stream is being coded as this affects
the context of the alarms for ETSI TR 101 290 priority 3 and the handling of AC3 Audio.
•
PID Display Mode: Options are Hex or Decimal. This determines how the PID Monitor View
displays the PID value.
•
Clear All Stats: Select enable, and then apply the change. All statistics will be reset.
•
Clear All Errors: Select enable, and then apply the change. All error conditions will be reset.
7880DEC-MP2HD-2 - 20
Figure 4-1 VistaLINK
®
Revision 1.0
PRO – Input Monitor