3. AD57G MONITORING FUNCTIONS
MELSEC-A
(2) Settings by using the AD57GP
Set the sprite frame in the same position and change the offset value so
that the display settings of the bar graphs representing planned num-
bers, actual numbers, and defective rates are done separately in order
to display the graphs side
by
side,
Settlng Items
Set Data
Trigger
Always
Starting point
L-UP
X
: 120
Y
: 90
Sprite frame
Finishing point
R-LOW X : 408
Y :
330
Display direction
Vertical
-
Planned
1
Actual
I
Defective rate
Offset
24
1
48
1
72
Offsetlwidth
Display format
Display
typelnumber
of elements
Monitor device
Width
1
24
S ~ a e e
1
96
Number of points
3
Data type
16-bit
Upper limit values
400
1
400
1
40 ' 1
Lower limit value
0
Type
Normal
Number of
-
elements
-
~p
Continuous1
random
Continuous
Paint panerns
*I
Displaying the actual defective rate is controlled by the sequence program (number of
defects
x 1000).
If a bar graph is displayed in this selling mode, setting the value in devices D330 to
D332
to
40
makes the bars on the screen
4%
longer.