STAC5 Ethernet Hardware Manual
Connecting an NPN Proximilty Sensor to Low Speed Differential Inputs
Analog Input
The MSSTAC5 drives feature one analog input. It can accept
a signal range of 0 to 5 VDC, ±5 VDC, 0 to 10 VDC or ±10
VDC. The drive can be configured to operate at a speed or
position that is proportional to the analog signal.
Use the ST Configurator software to set the signal range, offset,
deadband and filter frequency.
Connecting a Potentiometer to the Analog Input
Rev. 1.0
05/07/2013
+
12-24V
Proximity
Power
Sensor
Supply
-
Connecting a PNP Type Proximity Sensor to a an input
(When prox sensor activates, input goes low).
+
+
DC
NPN
Power
Proximity
Supply
Sensor
–
–
8
+5V OUT
cw
15
1-10k Ω
AIN
pot
ccw
7
GND
Connecting a Potentiometer to the Analog Input
+
output
PNP
IN3..IN6
IN/OUT2
–
INCOM
IN+
STAC5
output
IN-
20
8
inside drive
+5V OUT
15
Signal
AIN
Conditioning
7
GND
Need help?
Do you have a question about the MSSTAC5 and is the answer not in the manual?