Analog Input - Moons' MSSTAC5 Hardware Manual

Table of Contents

Advertisement

STAC5 Ethernet Hardware Manual
Connecting an NPN Proximilty Sensor to Low Speed Differential Inputs

Analog Input

The MSSTAC5 drives feature one analog input. It can accept
a signal range of 0 to 5 VDC, ±5 VDC, 0 to 10 VDC or ±10
VDC. The drive can be configured to operate at a speed or
position that is proportional to the analog signal.
Use the ST Configurator software to set the signal range, offset,
deadband and filter frequency.
Connecting a Potentiometer to the Analog Input
Rev. 1.0
05/07/2013
+
12-24V
Proximity
Power
Sensor
Supply
-
Connecting a PNP Type Proximity Sensor to a an input
(When prox sensor activates, input goes low).
+
+
DC
NPN
Power
Proximity
Supply
Sensor
8
+5V OUT
cw
15
1-10k Ω
AIN
pot
ccw
7
GND
Connecting a Potentiometer to the Analog Input
+
output
PNP
IN3..IN6
IN/OUT2
INCOM
IN+
STAC5
output
IN-
20
8
inside drive
+5V OUT
15
Signal
AIN
Conditioning
7
GND

Advertisement