Adjusting the Cable Guards

Each of the four castor wheels is fitted with a cable guard. These are
height adjustable and should be set as required for the installation.
WARNING! To avoid the risk of wheel collision with smaller
cables, all four cable guards must be set to a maximum
height clearance of 3 mm (0.12 in.) above the floor level.
1.
Loosen the locking knob on the side of the cable guard.
2.
Slide the cable guard to
the required height level
and secure in position
by re-tightening the
locking knob.
3.
Adjust the other three cable guards to the same level requirement.
Installation
!
MAX 3 mm (0.12 in.)