Adjusting Digital Micromirror Device (Dmd) Convergence - Christie CP2309-RGB Installation And Setup Manual

Hide thumbs Also See for CP2309-RGB:
Table of Contents

Advertisement

A
Right boresight cap screw
B
Right boresight set screw
C
Left boresight cap screw
D
Left boresight set screw
4. Turn the right boresight cap screw (A in the image in step 3) 1/16 of a turn clockwise.
5. Adjust the left boresight cap screw (C in the image in step 3) equally in the opposite direction.
6. If the quality of the projected image has not improved, turn the right boresight cap screw 1/16
of turn counter-clockwise.
Make sure the left adjuster is adjusted equally in the opposite direction.
7. Check the screen each time an adjustment is made.
The right-side adjustments affect the top right and bottom left points on the screen.
8. Once both cross hairs are in focus, lock the set screw for right boresight.
9. Repeat steps 5 to 8 for the left side.
10. Verify each corner of the screen is equally in focus.
If this is not the case, try adjusting vertical boresight.
Adjusting digital micromirror device (DMD)
convergence
A convergence problem occurs when one or more projected colors (red, green, blue) appears
misaligned when examined with a convergence test pattern.
Normally, the three colors should overlap precisely to form pure white lines throughout the image and
one or more poorly converged individual colors may appear adjacent to some or all of the lines.
Contact your Christie qualified service technician to correct digital micromirror device (DMD)
convergence issues.
CP2309-RGB Installation and Setup Guide
020-103078-04 Rev. 1 (11-2023)
Copyright
©
2023 Christie Digital Systems USA, Inc. All rights reserved.
If printed, please recycle this document after use.
Adjusting the image