Programming Codes
[ESC] [EM]P<n>
ASCII
[ESC] [EM] P<n>
Hexadecimal 1BH 19H 50H <n>
Decimal
<27> <25> <80><n>
IPCL
None
EPOS
None
Description This command activates the periodic status back feature.
automatically return an [ENQ]<20> status (See page Error! Bookmark
not defined.) on a periodic bases. The value of n is the period in 100 MS
intervals. This command is saved through power cycles. Once set it
need not be set again, however you can set it the same value repeatedly
as it is only saved if it is changed. In general it should not be changed on
a regular bases.
Where
n = Interval in 100 MS increments. IE 20 = 2 Seconds. Setting the value
to 0 disables the feature.
Note: Periodic status back can also be activated with the [ESC][EM]p command,
however it is not save during a power cycle.
[ESC] [EM]p<n>
ASCII
[ESC] [EM] p<n>
Hexadecimal 1BH 19H 70H <n>
Decimal
<27> <25> <112><n>
IPCL
None
EPOS
None
Description This command temporarily disables and enables the periodic status back
feature if previously activated with the [ESC][EM]P command.
Where
n = 0 disables PSB and n = (non zero) Enables PSB at the interval
defined by the [ESC][EM]P command.
If not previously activated with the [ESC][EM]P command, this command
will activate it but not save the value through a power cycle.
Where
n = Interval in 100 MS increments. IE 20 = 2 Seconds. Setting the value
to 0 disables the feature.
100-06908
®
Ithaca
Activate Periodic Status Back
Activate Periodic Status Back
Rev D
8000 Programmer's Guide
It will
Page 177
Need help?
Do you have a question about the Ithaca 8000 and is the answer not in the manual?