Endress+Hauser Proline Promass I 300 PROFINET Operating Instructions Manual page 237

Coriolis flowmeter
Table of Contents

Advertisement

Proline Promass I 300 PROFINET
Endress+Hauser
Assignable measured
variables
Switch output
Maximum input values
Open-circuit voltage
Switching behavior
Switching delay
Number of switching
cycles
Assignable functions
Relay output
Function
Version
Switching behavior
• Mass flow
• Volume flow
• Corrected volume flow
• Density
• Reference density
• Temperature
• Electronics temperature
• Oscillation frequency 0
• Oscillation damping 0
• Signal asymmetry
• Exciter current 0
The range of options increases if the measuring device has one or more
application packages.
DC 30 V, 250 mA (passive)
DC 28.8 V (active)
Binary, conductive or non-conductive
Configurable: 0 to 100 s
Unlimited
• Off
• On
• Diagnostic behavior
• Limit value
• Mass flow
• Volume flow
• Corrected volume flow
• Density
• Reference density
• Temperature
• Totalizer 1-3
• Flow direction monitoring
• Status
• Partially filled pipe detection
• Low flow cut off
The range of options increases if the measuring device has one or more
application packages.
Switch output
Relay output, galvanically isolated
Can be set to:
• NO (normally open), factory setting
• NC (normally closed)
Technical data
237